![background image](http://html1.mh-extra.com/html/daikin/super-multi-nx-c-series/super-multi-nx-c-series_service-manual_3794977224.webp)
SiE12-411
Check
Service Diagnosis
213
6.1.15 Hall IC Check
Check No.16
1. Check the connector connection.
2. With the power ON, operation OFF, and the connector connected, check the following.
∗
Output voltage of about 5 V between pins 1 and 3.
∗
Generation of 3 pulses between pins 2 and 3 when the fan motor is operating.
Failure of (1)
$
faulty PCB
$
Replace the PCB.
Failure of (2)
$
faulty hall IC
$
Replace the fan motor.
Both (1) and (2) result
$
Replace the PCB.
The connector has 3 pins, and there are two patterns of lead wire colors.