![background image](http://html1.mh-extra.com/html/daikin/super-multi-nx-c-series/super-multi-nx-c-series_service-manual_3794977137.webp)
Instruction
SiE12-411
126
System Configuration
NOTE
"
To set the clock
1. Press “CLOCK button”.
0:00
is displayed.
blinks.
2. Press “TIMER setting button” to set the
clock to the present time.
Holding down “
” or “
” button rapidly
increases or decreases the time display.
3. Press “CLOCK button”.
:
blinks.
"
Turn the breaker ON
•
Turning ON the breaker opens the flap, then
closes it again. (This is a normal procedure.)
C
TEMP
ON/OFF
POWERFUL
HOME LEAVE
MODE
TIMER
FAN
S
WING
S
ILENT
S
EN
S
OR
ON
CANCEL
OFF
1.
3
2
"
Tips for saving energy
•
Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps
save energy.
•
Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling
(heating) effect.
•
Clogged air filters cause inefficient operation and waste
energy. Clean them once in about every two weeks.
"
Please note
•
The air conditioner always consumes 15-35 watts of electricity even while it is not operating.
•
If you are not going to use the air conditioner for a long period, for example in spring or
autumn, turn the breaker OFF.
•
Use the air conditioner in the following conditions.
•
Operation outside this humidity or temperature range may cause a safety device to disable the
system.
Recommended temperature setting
For cooling: 26°C – 28°C
For heating: 20°C – 24°C
Mode
Operating conditions
If operation is continued out of this range
COOL Outdoor temperature:<3/4MK> 10 to 46 °C
<3/4MX> –10 to 46 °C
Indoor temperature: 18 to 32 °C
Indoor humidity: 80% max.
• A safety device may work to stop the operation.
(In multi system, it may work to stop the operation of the outdoor unit only.)
• Condensation may occur on the indoor unit and drip.
HEAT
Outdoor temperature:<3/4MX> –15 to 21 °C
Indoor temperature: 10 to 30 °C
• A safety device may work to stop the operation.
DRY
Outdoor temperature:<3/4MK> 10 to 46 °C
<3/4MX> –10 to 46 °C
Indoor temperature: 18 to 32 °C
Indoor humidity: 80% max.
• A safety device may work to stop the operation.
• Condensation may occur on the indoor unit and drip.
Summary of Contents for Super Multi NX C-Series
Page 6: ...SiE12 411 Table of Contents v Index i Drawings Flow Charts v...
Page 7: ...SiE12 411 vi Table of Contents...
Page 67: ...Specifications SiE12 411 56 Specifications...
Page 171: ...Instruction SiE12 411 160 System Configuration...
Page 225: ...Check SiE12 411 214 Service Diagnosis...
Page 295: ...SiE12 411 iv Index...