Field Settings from Remote Controller
SiUS331708EA
111
Field Settings and Test Operation
1.6.2 How to Select Operation Mode
Whether operation by remote controller will be possible or not for turning ON/OFF, controlling temperature or
setting operation mode is selected and decided by the operation mode given on the right edge of the table below.
: Factory setting
Do not select “timer operation possible by remote controller” if not using a remote controller. Operation by timer is
impossible in this case.
Example
↓
Rejection
↓
Rejection
↓
Rejection
↓
Acceptance
↓
Acceptance
ON by remote
controller
(Unified ON by
centralized remote
controller)
OFF by remote
controller
(Unified OFF by
centralized remote
controller)
OFF by
remote
controller
Temperature
control by
remote controller
Operation mode
setting by
remote controller
Control
mode is "1."
Control mode
Control by remote controller
Control mode
Operation
OFF
Temperature
control
Operation
mode setting
Unified operation,
individual operation
by centralized remote
controller, or
operation controlled
by timer
Unified OFF,
individual stop by
centralized remote
controller, or timer
stop
ON/OFF control
impossible by
remote controller
Rejection (Example)
Rejection (Example)
Rejection
(Example)
Rejection
Acceptance
0
Rejection
10
Acceptance
(Example)
Acceptance
(Example)
1(Example)
Rejection
11
OFF control only
possible by
remote controller
Acceptance
Rejection
Acceptance
2
Rejection
12
Acceptance
Acceptance
3
Rejection
13
Centralized
Acceptance
Rejection
Acceptance
4
Rejection
14
Acceptance
Acceptance
5
Rejection
15
Individual
Acceptance
Rejection
Acceptance
6
Rejection
16
Acceptance
Acceptance
7
Rejection
17
Timer operation
possible by
remote controller
Acceptance
(During timer at ON
position only)
Acceptance
(During timer at ON
position only)
Rejection
Acceptance
8
Rejection
18
Acceptance
Acceptance
9
Rejection
19
Local remote controllers cannot set
temperature or operation mode when
the system is under centralized control
and
CENTRAL CONTROL
is displayed
on the screen.
BRC1E73
Summary of Contents for RXSQ24TAVJU
Page 1: ...Service Manual SiUS331708EA RXSQ24 36 48 60TAVJU Heat Pump 60 Hz...
Page 290: ...Wiring Diagrams SiUS331708EA 277 Appendix RXSQ48TAVJU 3D109546A...
Page 291: ...SiUS331708EA Wiring Diagrams Appendix 278 RXSQ60TAVJU 3D109547A...
Page 295: ...SiUS331708EA Wiring Diagrams Appendix 282 FXZQ05 07 09 12 15 18TAVJU 3D110443A...
Page 298: ...Wiring Diagrams SiUS331708EA 285 Appendix FXEQ07 09 12 15 18 24PVJU 3D098557A...
Page 300: ...Wiring Diagrams SiUS331708EA 287 Appendix FXSQ05 07 09 12 15 18 24 30 36 48 54TAVJU 3D110467B...
Page 301: ...SiUS331708EA Wiring Diagrams Appendix 288 FXMQ07 09 12 15 18 24 30 36 48 54PBVJU 3D093209B...
Page 302: ...Wiring Diagrams SiUS331708EA 289 Appendix FXHQ12 24 36MVJU 3D048116C...
Page 303: ...SiUS331708EA Wiring Diagrams Appendix 290 FXAQ07 09 12 18 24PVJU 3D075354C...
Page 309: ...SiUS331708EA Wiring Diagrams Appendix 296 VAM1200GVJU 3D073270D...