Appendix A
75
12. For VID 1 we will select the port membership in order for Port 1, Port 2, Port3 and Port 4 as 'untagged',
'nonmember', 'nonmember', and 'nonmember'.
The results look like this.
By making Port3&4 nonmembers of VID1, we have blocked any normal traffic between those two clients. They
are isolated from each other.
The next step will be to create the VIDs for 10 and 20. We will make Port3&4 untagged members of VID10 and
20 respectively. Port 1 (fiber) will be Tagged member for each VLAN.
The resulting Static VLAN table will look like this:
This simple VLAN scheme will now be working such that PC-A can only connect to Server A and PC-B can
only connect to Server B.
When assigning static VLAN ID, any ID from 1-4094 can be chosen. However, the maximum number of VID
table entries for the
1000EAS
is 64 static VLANs.
Operate:[Create] VLAN ID:[ 1]
Port 1:[ ],Port 2:[ ],Port 3:[ ],Port 4:[ ]
...............................................................................
Operate VLAN Table: Select Port 1 Membership.
<1> UnModified <2> UnTagged <3> Tagged <4> NonMember
<ESC>:Previous
Page.
*********************************************
*** CTC UNION TECHNOLOGIES CO., LTD. ***
*** FRM220-1000EAS Ver:3.240 ***
*********************************************
<< Remote A Static VLAN Table Configuration >>
Item | VLAN ID | Port 1 | Port 2 | Port 3 | Port 4
01 | 1 | Untagged | Nonmember | Nonmember | Nonmember
*********************************************
*** CTC UNION TECHNOLOGIES CO., LTD. ***
*** FRM220-1000EAS Ver:3.240 ***
*********************************************
<< Remote A Static VLAN Table Configuration >>
Item | VLAN ID | Port 1 | Port 2 | Port 3 | Port 4
01 | 1 | Untagged | Nonmember | Nonmember | Nonmember
02 | 10 | Tagged | Nonmember | Untagged | Nonmember
03 | 20 | Tagged | Nonmember | Nonmember | Untagged
<N><PageDown>:Show Next Page.
<P><PageUp> :Show Previous Page.
<DownArrow>:Show Next Item.
<UpArrow> :Show Previous Item.
<V> :VLAN Table Operation.
<R> :Reset Static 802.1Q VLAN Settings.
<C> :Clear Static 802.1Q VLAN Table.
<ESC>:Go to Port VID Configuration Page.
Summary of Contents for FRM220-NMC
Page 1: ...FRM220 NMC Network Management Controller...
Page 2: ......
Page 7: ...Table of Contents iii...
Page 8: ......
Page 104: ...Appendix A 102 A 3 FRM220 FXO FXS In band Managed POTS PSTN Fiber Converter...
Page 105: ...Appendix A 103...
Page 180: ......
Page 181: ......
Page 182: ......