Appendix A
38
A.1.3 Block Diagram of 10/100i
(For reference only)
A.1.4 FRM220-10/100i Console Configuration
From the main menu of the FRM220 NMC console, select the slot number containing the 10/100i line card.
This Chassis ID:[00] Cascaded:[Yes] Monitored Chassis ID:[00]
SLOT #02 > FRM220-10/100I [Local ] [ Ver:1.100-1.275-0.000-0.000 ]
<1>: Port Active:[Enable ]
UTP Link:[Up ] Rx Active:[On ]
<2>: Negotiation:[Auto ]
<3>: Speed: [100 ]
<4>: Duplex: [Full]
FX Link:[Up ] Rx Active:[On ] FEF:[Off ] Remote PWR:[OK ]
<5>: Loop Back Test:[Off ] Status:[----]
<6>: Operation Mode: [Switch ]
<7>: Ingress Rate Limit(IRL) Mode: [No Limit] [100.0M]
<8>: Egress Rate Limit(ERL) Mode: [No Limit] [100.0M]
<9>: Link Fault Pass Through(LFP): [Disable]
<A>: Auto Laser Shutdown(ALS): [Disable]
<B>: Send Remote Hardware Reset <M>: In Band Management:[Enable ]
<C>: Port Reset <K>: Set to default
Small Form Pluggable(SFP):[No ] Digital Diagnostic(D/D) Function:[No]
<D>: Go to the D/D Functions menu. <N>: Go to the Remote menu.
<ESC>: Go to previous menu. Please select an item.
The chassis ID in a stacked set is shown on the first line.
The next line shows the slot number, card type, location and version. In this example the card's hardware version is 1.100 and
the firmware version is 1.275.
<1>
When the port is disabled, the PHY becomes inactive and all Ethernet traffic will be blocked.
<2> <3> <4>
Control the auto-negotiation (n-way) and forced mode Ethernet settings.
<5>
Performs an OAM loop back test, non-intrusive to client's transmitted data (i.e. no traffic is blocked).
<6>
Configures the MC between either switch mode (store & forward) or converter mode (jumbo frame support).
<7>
Sets a rate limit on packets passing from UTP to Fiber in either multiples of 32K or 512K
<8>
Sets a rate limit on packets passing from Fiber to UTP in either multiples of 32K or 512K
<9>
Enables or disables the Link Fault Pass-Through (LFP) function
<A>
Enables or disables the Auto Laser Shutdown (ALS) function.
<B>
Send a hardware reset to remote unit via fiber (must enable reception from the remote side first)
<C>
Performs a reset on the local switch port.
<D>
View the transceiver's digital diagnostics (DD) if available. (only for SFP modules that support DD function)
<N>
Go to manage the remote via OAM.
<
ESC
> Escape back to previous menu.
Switch
OAM
FIFO
MAC
MAC
μ
P
RS485 driver
Reg.
Edg
e Conn
ector
12VDC
MII
LEDs
FX PHY
TP P
HY
MAC
Card Face
Summary of Contents for FRM220-NMC
Page 1: ...FRM220 NMC Network Management Controller...
Page 2: ......
Page 7: ...Table of Contents iii...
Page 8: ......
Page 104: ...Appendix A 102 A 3 FRM220 FXO FXS In band Managed POTS PSTN Fiber Converter...
Page 105: ...Appendix A 103...
Page 180: ......
Page 181: ......
Page 182: ......