A.2.3 Factory Reset Procedure
Apply power to the
1000EAS
and allow 30 seconds to fully boot. Using a pencil or ball-point pen, press the
'DEFAULT' recessed push-button switch (located on the face plate) and hold for 9~10 seconds. DO NOT POWER
OFF. Allow the unit to again fully reboot. The defaults are:
IP=10.1.1.1
netmask=255.0.0.0
GW=10.1.1.254
TFTP server=10.1.1.100
The username and password are both reset to 'admin' if enabled.
A.2.4 Installation
A.2.4.1 Chassis Options
Note: This converter card can be placed in any
FRM220
series chassis, including the single slot CH-01, two
slot CH02-NMC or the full twenty slot CH-20 chassis. Chassis with built-in power are available with single AC (90-
240VAC), single DC (18~75VDC), dual AC, dual DC or AC plus DC combo. The single slot chassis with external
power adapter works with AC source voltage only with the provided 90~240VAC 12VDC@400mA switching
adapter.
Figure A.2.2 Chassis options for
FRM220-1000EAS
card
!! Follow all ESD precautions when handling the card and SFP modules !!
CH02-NMC-XX Chassis (XX=
AC, DC, AA, DD or AD)
FRM220-CH20
CH01-XX Chassis (XX=
AC, DC, AA, DD or AD)
FRM220-CH01, single slot
chassis
Requires external AC to DC
12V switching adapter.