Output Type
Parameter
Description
Default Configuration
Output is constant
The output will change its state when an alarm
occurs
Disable
Time Zone Assignment
Parameter
Description
Default Configuration
Time Zone Assigned to Output
If a time-zone is assigned to an output it will turn
the output on when the time-zone starts and turn
the output off when it finishes.
disable
Signals to Output
Parameter
Description
Default Configuration
Mains Fail to Output
This option is used to assign a Mains Fail alarm to
an Output
Disable
Fuse Fail to Output
*Not in use
Batt Low to Output
This option is used to assign a Battery Low alarm to
an Output
disable
Monitor output fail to Output
This option will cause the Output to short single
pulse when any area is armed and monitoring
company has kissed off the message.
disable
Output tamper alarm to Output
This option is used to assign a Output tamper
alarm to an Output. When output tamper alarm
occurs, any output can be turned to on
disable
works in ARM mode only
(Shmulik decision )
Communication fail to Output
This option is used to assign a Communication
Failure alarm to an Output
disable
Radio Zone Supervised Fail to
Output
This option is used to assign a Radio Detector
Supervisory Fail alarm to an Output
disable