Outdoor Zone
A special feature for detectors that installed outside the premises,
which mainly indicates to the control Monitoring center that the
alert came from an external and not internal detector, such as the
code according to the CMS.
Zone will send Outdoor alarm (1136) in instead alarm (1130)
disable
Handover zone
A Handover Zone is one that its entry delay will apply provided a
Non-Handover entry zone is triggered first. If no other entry delay
zones are triggered before the handover zone the entry delay on
that zone does not apply and the alarm will become instant (no entry
delay)
No Zone selected
Manually bypassed
zone
Zone can be manually bypassed while in the disarmed state. Once
the area with the bypassed zone has been armed and then disarmed,
the manual bypass is canceled and the zone must be manually
bypassed again before arming if required.
All zones selected
Auto bypassed zone
Zone will be auto-bypassed if unsealed at the expiry of the exit delay.
If a zone is unsealed at the time of arming and remains unsealed
when the exit delay expires and this option is on for that zone it will
be automatically bypassed by the panel. If the zone seals after that
time it will be re-instated automatically and can then cause an alarm.
On disarming of the alarm any auto-Bypasses are removed
No Zone selected
Disable Zone Tamper
If this option is turned ON then the zone tamper will be disabled,
opening or removing the zone from the wall will not cause to tamper
alarm on panel.
No Zone selected
Area Assignment
Parameter
Description
Default Configuration
Zone assigned to Areas
This option assigns the Zone to Area. If a Zone is assigned only to
one area, it will activate if specified area is armed. If zone assigned
to more than one area, it will activate only when all assigned areas
are armed. By default all zones assigned to Area 1.
All Zones assigned to
Area 1 only.
Working Mode
Parameter
Description
Default Configuration
Normal
Zone without any special behavior.
All zones selected
24-hour zone
If this option is ON the zone will be constantly monitored regardless
of the arm/disarm state of the panel. If the 24 Hour zone also has
an entry delay programmed, this delay will apply. Once the alarm
has been generated it must be cleared by entry of a valid User code
No Zones selected