24-hour
auto-reset zone
If this option is ON the zone will be constantly monitored regardless
of the arm/disarm state of the panel. Once an alarm has been
generated with a 24-Hour Auto-reset zone, the alarm will be reset
automatically once the zone is closed. If the 24-Hour zone also has
an entry delay programmed, this delay will apply. If the 24-Hour
zone activates but then resets before the entry delay expires no
alarm will be generated. This feature can be useful for monitoring
plant type alarms such as freezer alarms.
No Zones selected
24-hour fire zone
If this option is ON the zone will be constantly monitored regardless
of the arm/disarm state of the panel. If the 24-Hour Fire zone also
has an entry delay programmed, this delay will apply. Once the
alarm has been generated it must be cleared by entry of a valid User
code.
No Zones selected
24-hour Water zone
If this option is ON the zone will be constantly monitored regardless
of the arm/disarm state of the panel. If the 24-Hour Water zone
also has an entry delay programmed, this delay will apply. Once the
alarm has been generated it must be cleared by entry of a valid User
code.
No Zones selected
24-hour Gaz zone
If this option is selected the zone will be constantly monitored
regardless of the arm/disarm state of the panel. Once the alarm has
generated, it must be cleared by entry of a valid User code.
24-hour High
temperature zone
If this option is selected the zone will be constantly monitored
regardless of the arm/disarm state of the panel. Once the alarm has
generated, it must be cleared by entry of a valid User code. This is
a special feature that the HIGH temperature alarm event replaces
the regular alarm (open/close) event from a detector
24-hour Low
temperature zone
If this option is selected the zone will be constantly monitored
regardless of the arm/disarm state of the panel. Once the alarm has
generated, it must be cleared by entry of a valid User code. This is
a special feature that the LOW temperature alarm event replaces
the regular alarm (open/close) event from a detector
Chime
If this option is ON, the zone will operate Chime mode when
disarmed. When the alarm is armed the Chime Mode is disabled for
this zone. A Chime zone can sound the keypad buzzer or operate an
output to indicate that the zone is unsealed. It is normally used to
monitor areas during the daytime
No Zones selected
NOTE :
please note that if zone is
set to working mode “chime” zone in
C.P FW 82.xx , the zone working mode
changes to “ 24H Gaz Zone” on
upgrading C.P FW to 84.41
Permanent chime
If this option is ON, the zone will operate Chime mode when armed
or disarmed. When the alarm is armed the zone will continue to
only be a Chime Mode Zone and will not cause a burglar alarm. A
Chime zone can sound the keypad buzzer or operate an output to
indicate that the zone is unsealed
No Zones selected
Zone is key switch
This option enables zone as a keyswitch function
No Zones selected