Alarm to Outputs
(cont)
Parameter
Description
Default Configuration
Zone tamper to outputs
Zone tamper can trigger selected output(s) for
local alarm signaling.
No Outputs selected
Chime zone alarm to outputs
If a zone is programmed as a Chime zone and it
activates, the zone can trigger selected Outputs
for local alarm signaling. The output will operate
for the Chime to Output time at location. The zone
must clear before the output can be activated
again
No Outputs selected
Zone near alarm to outputs
If zones are programmed for near and verified
alarms, it is also possible to get an indication of a
near alarm from any of the 16 outputs using this
program location. A near alarm is the first alarm
during an armed period
No Outputs selected
Zone verified alarm to outputs
If zones are programmed for near and verified
alarms, it is also possible to get an indication of a
verified alarm from any of the 16 outputs using
this program location. A verified alarm is the
second alarm from a different zone to the one that
caused the near alarm and must happen within 45
minutes of the near alarm
No Outputs selected
Delays and timers
Parameter
Description
Default Configuration
Armed zone entry delay
time (seconds)
Each Zone has it's own Entry Delay time when in the Full Armed
State. The delay can be programmed from 0 to 9999 seconds in
one-second increments. If the entry delay is set to 0 the zone
will be an instant zone.
All zones are selected
Stay mode entry delay
time (seconds)
Each Zone has it's own Entry Delay time when in Stay Mode.
The delay can be programmed from 0 to 9999 seconds in one-
second increments. If the entry delay is set to 0 the zone will be
an instant zone.
All zones are selected
Zone Sensor watch-time
(minutes)
If value of this option is greater than zero then zone will be
checked to see that it operates during the disarmed state. If it
is not operated within the specified time a 'Sensor-watch' alarm
will be generated. This feature is designed to detect a faulty
zone that is not operating normally or one that has had its
detection area blocked. The timer is stopped when the area
assigned to the zone is armed and resumes with the specified
value when disarmed again. The timer is reset back to the
original value every time the zone operates while disarmed.
The range of values from 0 to 9999 minutes.
All zones are selected