Page 45
option 7 and that will play during the pre-alert time (once again with the volume settings applied) changing to the
pulsed 1khz tone for the exit delay.
STAY MODE ARM EXIT BEEPS to OUTPUT
STAY MODE ARM EXIT BEEPS to OUTPUT -
P66E 1-32E (1 = Area 1, 32 = Area 32)
Value = 01-32 for Outputs 1-32
Option 01 = Output 1 - Option 32 = Output 32
Sometimes it can be useful to extend the exit beeps, that occur at a keypad, to be present on an audible device on
the exit path. This option allows the exit beeps during the arming of stay mode to be assigned to any of the 32
outputs. The Pulse time (P39E) sets the length of each beep.
AREA DELINQUENCY DELAY
AREA DELINQUENCY DELAY -
P67E 1-32E (1 = Area 1, 32 = Area 32) (Value 0-99 Days)
Each Area can have their own Delinquency time. The delinquency time monitors the arm/disarms of each Area. If an
Area has not been armed within the set number of days a delinquency report will be sent. Each time an Area is
armed the delinquency timer is reset. A value of “0” disables the delinquency monitoring.
NOTE: If the default value of “0” is changed at this location (eg a value of 10 is entered meaning 10 days), the next
time the area is armed a delinquency restore message will be sent via the dialler (Event type 454) as a test that the
function is operating.
AUTOMATIC ARM/DISARM TIMEZONE
AUTOMATIC ARM/DISARM TIMEZONE -
P68E 1-32E (1 = Area 1, 32 = Area 32)
Value = 01-32 for Time-Zone 1-32
Option 01 = Time-Zone 1 - Option 32 = Time-Zone 32
If Options 2 or 3 are turned on at location P46E then the Area can be automatically armed or disarmed by a time-
zone/s. You can assign more than one time-zone to each Area. If assigning multiple time-zones you should insure
that they do not overlap as this could cause confusion. A Time-zone would typically be 0830-1700 Monday-Friday.
An area will turn on when the Time-zone ends (eg 1700) and turn off when a Time-zone starts (eg 0830).
Program LCD KP “Area” Name
Program LCD KP “Area” Name Text
- P69E 1-32E
Each Area can have a custom name that will be displayed when in Memory Mode. The FULL LCD KP “Area” name
text is programmed at this location.
BULK COPY AN AREA TO A RANGE OF AREAS
Bulk COPY an Area to a range of Areas
- P70E
It is possible to set up a single Area and then copy the programmed data for that area to a range of areas. For
example if Area 5 was set up as a template and that data was required to be copied to Areas 6 to 12 inclusive then
once area 5 has been fully programmed by entering in P70E 5E followed by 6E then 12E the panel will copy Area 5’s
settings to all areas from 6 to 12. This process can be repeated many times with different Areas set up as a template
and a different range of area addresses.
ZONE ACTIVITY TIMER
Zone Activity Timer
- P4071E 1-32E (Value 0-255 minutes) - If arm at the end of a time zone or arm on no activity
(P46E option 8) is turned on the area will begin arming. If this address is set to 0 the area will being arming when the
time zone ends or immediately if the time zone function is not assigned. If a value from 1-255 is set the area will start
the programmed time before it will begin arming. Any zone activity during this time will reset the time back to it’s full
value. For the activity timer to expire there must be no zone activity. While there is activity the panel will hold off
arming.
ARMING PRE-ALERT TIMER
Arming Pre-alert Timer
- P4072E 1-32E (Value 0-255 seconds) - If arm at the end of a time zone or arm on no
activity (P46E option 8) is turned on the area will begin arming once the activity timer (P4071E) has expired. If this
address is set to 0 the area will being arming as soon as the activity timer expires. If a value from 1-255 is set the
area will start the programmed time before it will begin arming. If exit delay to outputs (P65E) is turned on the output