sent for the zone that activated. If the zone that activated is still unsealed when the 45 minute timer
expires, a zone bypass for that zone will be sent and the zone will remain bypassed until the area is
disarmed. Any new alarms after the timer has expired will send another Near Alarm report. If a second
alarm on a different zone occurs within 45 minutes of the Near alarm, an Intrusion Verified alarm report
will be sent. This format only applies to Contact ID and Pager reporting. Turning this option on will stop
zone alarms from being reported in Domestic & Voice formats as there are no messages for near and
confirmed alarms. You must turn this option off if using Domestic or Voice formats.
Option 2
Area will Arm at the end of Time-Zone
- The panel is capable of automatically arming on a Time-Zone.
If this option is turned on and a Time-Zone is selected at P68E, the Area will automatically arm when the
Time-Zone ends. If the panel cannot arm because it is not “Ready”, a fail to arm report will be sent. Also
if there is a zone activity time (P4071E) programmed the arming will be delayed by that time period.
Every time a zone in the area is triggered it resets the zone activity timer and delays arming while there
is activity detected. Once the zone activity timer expires the panel starts the Pre-alert warning (P4072E).
Any zone activity during the Pre-alert time will reset the Pre-alert timer and start the activity timer again.
If the Pre-alert timer expires the panel starts the normal exit delay. During the exit delay arming can only
be stopped by entry of a valid user code.
Option 3
Area will Disarm at the start of Time-Zone
- The panel is capable of automatically disarming on a
Time-Zone. If this option is turned on and a Time-Zone is selected at P68E, the Area will automatically
disarm when the Time-Zone starts.
Option 4
Assign Chirps to Access Tags
- If the panel is being Armed or Disarmed by an Access Tag/Card from
a proximity reader it is possible to link the pendant chirps programming (P50E-P53E) to Arming or
Disarming via the Access Tag or Card. If this option is On the chirps will apply to Access Tag/Cards. If
the chirps are required to be displayed at the reader LED, the minimum pulse timer for the output (P39E)
must be a value of 10.
Option 7
Cannot Arm if Zone Unsealed at end of Exit Delay
- If this option is turned on and a zone becomes
unsealed as the exit delay expires the panel will fail to arm and report this via the dialler. The unsealed
zone must be corrected and the system re-armed again.
Option 8
Arm on no Activity
- If this option is turned ON the area will automatically arm at any time when there is
no zone activity detected. For this option to work at any time the area must NOT have option 2 above
turned on or a time zone (P68E) assigned. If there is a zone activity time (P4071E) programmed the
arming will be delayed by that time period. Every time a zone in the area is triggered it resets the zone
activity timer and delays arming while there is activity detected. Once the zone activity timer expires the
panel starts the Pre-alert warning (P4072E). Any zone activity during the Pre-alert time will reset the Pre
-alert timer and start the activity timer again. If the Pre-alert timer expires the panel starts the normal exit
delay. During the exit delay arming can only be stopped by entry of a valid user code.
AREA ARM INDICATION to OUTPUT
AREA ARM INDICATION to OUTPUT -
P47E 1-32E (1 = Area 1, 32 = Area 32)
Value = 01-32 for Outputs 1-32
Option 01 = Output 1 - Option 32 = Output 32
For monitoring purposes an Arm indication can be assigned to an Output. Each Area can have a separate arm
indication assigned to a different output if required.
AREA STAY ARM INDICATION to OUTPUT
AREA STAY ARM INDICATION to OUTPUT -
P48E 1-32E (1 = Area 1, 32 = Area 32)
Value = 01-32 for Outputs 1-32
Option 01 = Output 1 - Option 32 = Output 32
For monitoring purposes a Stay Arm indication can be assigned to an Output. Each Area can have a separate
indication assigned to a different output if required.
AREA DISARM INDICATION to OUTPUT
AREA DISARM INDICATION to OUTPUT -
P49E 1-32E (1 = Area 1, 32 = Area 32)
Value = 01-32 for Outputs 1-32
Option 01 = Output 1 - Option 32 = Output 32