Page 22
If no buttons are pressed for 30 minutes the panel will automatically exit program mode
Note:
While in Program Mode all Tampers and 24 hour alarms are disabled which allows quiet access to the
panel, detectors and external siren units, etc. On exiting program mode, all inputs are scanned and if any tampers
or 24Hr alarms are present an activation will occur.
TYPICAL PROGRAM SEQUENCE
The programming sequence follows this pattern;
<
PROGRAM
> - <1,2 or 3 digit program address> - <
ENTER
>
(Program Address)
1 short beep if OK - 1 long beep if error, THEN
<
PROGRAM
> - <1,2, 3 or 4 digit sub-address> - <
ENTER
>
(Sub-Address)
3 short beeps if OK - 1 long beep if error
The keypad will display current value or status
Enter the new value or option
<New Value> - <
ENTER
>
3 short beeps if OK - 1 long beep if error
Throughout this manual you will see program instructions expressed as per the example below
P 1 E 1-2000 E
Using the above example the <P> represents the <
PROGRAM>
key and <E> represents the <
ENTER>
key.
<1> refers to the address for programming User Codes and <1-2000> refers to Users 1-2000.