Page 85
Assigning a Time-zone to an Output
P44E
1-32E
Time-zones that will control Outputs 1-32
-
Value = Time-zone 01-32 (Default = All Off)
Page 38
(NOTE: If a TZ has turned an Output ON the TZ will override any reset time programmed for the Output. The reset, pulse or chime timers can
resume controlling the Output once the TZ has ended and the output is OFF. The CONTROL to Output function is the only operation that can
override the Output while the TZ is active.)
+++++Areas+++++
Area 1-32 Options A
P45E
1-32E
Area 1-32 Options A
1 = Arm Button Required Before Code to Set
Page 39
(Default = All Off)
2 = Stay Button Required Before Code to Set Stay Mode
3 = Code required to Set
4 = Code Required to Bypass Zones
5 = Spare
6 = Send Arm at the end of the Exit Delay
7 = Can Arm only if All Zones are Sealed (Ready)
8 = Can Arm Stay Mode only if All Zones are Sealed (Ready)
Area 1-32 Options B
P46E
1-32E
Area 1-32 Options B
1 = Near and Confirmed Alarm reporting for All zones in this Area (CID only)
Page 39
(Default = All Off)
2 = Area will arm at end of time-zone
3 = Area will disarm at beginning of time-zone
4 = Assign Chirps to Access tags
5 = Spare
6 = Spare
7 = Cannot Arm if Zone Unsealed at end of Exit Delay
8 = Arm on no Activity
Area 1-32 Arm Indication to Output
P47E
1-32E
Area 1-32 Arm Indication to Output
-
Value 01-32 (for Outputs 1-32)
Page 40
(Default = All Off)
Area 1-32 Stay Arm Indication to Output
P48E
1-32E
Area 1-32 Stay Arm Indication to Output
-
Value 01-32 (for Outputs 1-32)
Page 40
(Default = All Off)
Area 1-32 Disarm Indication to Output
P49E
1-32E
Area 1-32 Disarm Indication to Output
-
Value 01-32 (for Outputs 1-32)
Page 40
(Default = All Off)
(NOTE: If an Area Disarm has turned an Output ON this will override any reset time programmed for the Output. The reset, pulse or chime timers
can resume controlling the Output once the Area is armed and the output is OFF. The CONTROL to Output function is the only operation that can
override the Output while disarmed.)
Area 1-32 Pendant (or Access Tag) Arm Chirp to Output
P50E
1-32E
Area 1-32 Arm Chirp to Output
-
Value 01-32 (for Outputs 1-32)
Page 40
(Default = All Off)
(One chirp to the output for arm)
Area 1-32 Pendant (or Access Tag) Stay Arm Chirp to Output
P51E
1-32E
Area 1-32 Stay Arm Chirp to Output
-
Value 01-32 (for Outputs 1-32)
Page 41
(Default = All Off)
(One chirp to the output for stay arm)
Area 1-32 Pendant (or Access Tag) Disarm Chirp to Output
P52E
1-32E
Area 1-32 Disarm Chirp to Output
-
Value 01-32 (for Outputs 1-32)
Page 41
(Default = All Off)
(Two chirps to the output for disarm)
Area 1-32 Pendant Stay (or Access Tag) Disarm Chirp to Output
P53E
1-32E
Area 1-32 Stay Disarm Chirp to Output
-
Value 01-32 (for Outputs 1-32)
Page 41
(Default = All Off)
(Two chirps to the output for disarm)
Area 1-32 Arm Pulse to Output
P54E
1-32E
Area 1-32 Arm Pulse to Output
-
Value 01-32 (for Outputs 1-32)
Page 41
(Default = All Off)
Area 1-32 Stay Arm Pulse to Output
P55E
1-32E
Area 1-32 Stay Arm Pulse to Output
-
Value 01-32 (for Outputs 1-32)
Page 41
(Default = All Off)
Area 1-32 Disarm Pulse to Output
P56E
1-32E
Area 1-32 Disarm Pulse to Output
-
Value 01-32 (for Outputs 1-32)
Page 42
(Default = All Off)
Area 1-32 Stay Disarm Pulse to Output
P57E
1-32E
Area 1-32 Stay Disarm Pulse to Output
-
Value 01-32 (for Outputs 1-32)
Page 42
(Default = All Off)
Area 1-32 Armed Mode Exit Delay Beeps to Keypad
P58E
1-32E
Area 1-32 Armed Exit Delay Beeps to Keypad
-
Value 01-32 (for Keypads 1-32)
Page 42
(Default, Area 1 = All On, Areas 2-32 = All Off)