![Crow RUNNER 8/64 Installation & Programming Manual Download Page 10](http://html1.mh-extra.com/html/crow/runner-8-64/runner-8-64_installation-and-programming-manual_2689361010.webp)
Page 10
SELECTIVE ARM/DISARMING with MULTIPLE AREAS
At software version V225 a new method for selective arm/disarm when multiple areas are assigned to a
user was added to make it more flexible. To use this new selective arm/disarm you must turn ON option 6
at P25E13E.
If a user has many assigned areas they can chose to select which area or areas they would like to arm or
disarm. The areas assigned to the user must have “ARM Before Code” selected for all of the areas (P45E
option 1 ON) and all areas assigned to the user must be assigned to their keypad (P71E) and the ARM
button (P74E).
For example User 1 has 10 assigned areas and they are using Keypad # 1. The options to program are:
P2E1E User 1 has areas 01,02,03,04,05,06,07,08,09,10.
P45E1-10E Areas 1-10 have option 1 ON.
P71E1 Keypad 1 has areas 01,02,03,04,05,06,07,08,09,10.
P74E1 Keypad 1 “ARM” button has areas 01,02,03,04,05,06,07,08,09,10
When User 1 enters ARM - CODE - ENTER they will be presented with a list of areas to arm.
The display would look like this (only 6 areas can be displayed at one time):
All displayed areas are highlighted so they are ready for Arming. Below this selection line will be the cus-
tomised text name for the currently selected area (eg if area 01 was named “Reception PIR” that name
will appear underneath the selected area number). The currently selected area is area 01 because it is
inside the >< brackets. To select the next area and also see the other areas press the “BYPASS “ but-
ton to move the display to the right. To move back press the “ “ button to move back to the left.
If all the selected areas are to be armed simply pres the “ENTER” button to start arming of all areas.
To remove an area you can press the “ARM” button when the required area is selected. It will change to
being un-highlighted as shown in the example below where area 01 was removed from the arming list.
By default all assigned areas will be highlighted meaning they are all going to arm. If the user wants to
reverse that selection so that all areas are not highlighted (eg none will arm) they can press 00. To
change it back the user can press 99 to select ALL areas again. If a user has a large number of areas as-
signed but they only want to arm a few of them they can press 00 to deselect all areas then use the
“ARM” button to select the few they want to arm. If they want to arm most of the areas but exclude just a
few they would start off with all areas selected (99) then simply deselect the few they don’t want using the
“ARM” button. Once the selection has been made they simply press the ENTER button to arm the se-
lected areas.
The same situation works for disarming only the user presses CODE - ENTER and they are presented
with a list of areas to disarm. The selection toggle with the “ARM” button and the 00 & 99 functions work
the same during disarm.
Area/s to arm
> <
Reception PIR
01
02 03
06
05
04
Area/s to arm
> <
Reception PIR
01
02 03
06
05
04