Page 11
2k2
Ta mper
4k7
8k2
Ta mper
Alarm or Key-sw itch 1 Contact
Alarm or Key-sw itch 2 Contact
NC or NO
NC or NO
INPUTS
The
RUNNER
4
8/6
control board has 9 separate programmable monitored analogue inputs,
8 x
Programmable, multi-state zone inputs
1 x
Programmable tamper input
Each input must be terminated with the appropriate value or combination of end-of-line resistors,
even if the input is unused.
ZONE INPUTS
- Each of the 8 zone inputs can be assigned one of the following End of Line (EOL) configuration
options,
Zone EOL Type (P125E)
Input Resistor
Comments
0
(Short circuit)
Loop EOL
1
1k (Brown, Black, Red)
Single EOL
2
1k5 (Brown, Green, Red)
Single EOL
3
(P126E “Vibration Mode” only
supports this EOL value)
2k2 (Red, Red, Red)
Single EOL
4
3k3 (Orange, Orange, Red)
Single EOL
5
3k9 (Orange, White, Red)
Single EOL
6
4k7 (Yellow, Violet, Red)
Single EOL
7
5k6 (Green, Blue, Red)
Single EOL
8
6k8 (Blue, Grey, Red)
Single EOL
9
10k (Brown, Black, Orange)
Single EOL
10
12k (Brown, Red, Orange)
Single EOL
11
22k (Red, Red, Orange)
Single EOL
12 (series)
2k2 Tamper, 4k7 Zone
Zone & Tamper
13 (series)
3k3 Tamper, 6k8 Zone
Zone & Tamper
14 (series)
2k2 Tamper, 4k7 Low Zone, 8k2 High Zone Zone Doubling, with Tamper
15 (series)
4k7 Low Zone, 8k2 High Zone
Zone Doubling, No Tamper
16 (parallel)
4k7 Low Zone, 8k2 High Zone
Zone Doubling, No Tamper
Type 1-11 (Single EOL no Tamper)
Type 14 (Zone Doubling with Tamper)
n/c
n/o
EOL Resistor
Type 0 (Short/Loop Circuit)
n/c
Type 12-13 (Single Zone with Tamper)
2k2 or 3k3
Alarm Contact
n/c or n/o
4k7 or 6k8
Ta mper Resistor