Page 52
as lights, etc and you wish to be able to turn them On or Off from a keypad. By limiting the access to Outputs via the
<CONTROL> button you can avoid conflict with alarm outputs (eg the User can be denied access to outputs that are
being used for alarm functions).
KEYPAD PANIC ALARM to OUTPUT
KEYPAD PANIC ALARM (<CONTROL> & <CHIME>) to OUTPUT -
P84E 1-32E Value = 01-32 for Outputs 1-32
Option 01 = Output 1 - Option 32 = Output 32
A Keypad generated Panic Alarm (pressing <CONTROL> & <CHIME> together) can be assigned to an Output or
multiple Outputs. This can be used to operate an audible or visual alarm connected to the Output.
KEYPAD FIRE ALARM to OUTPUT
KEYPAD FIRE ALARM (<A> & <B>) to OUTPUT -
P85E 1-32E Value = 01-32 for Outputs 1-32
Option 01 = Output 1 - Option 32 = Output 32
A Keypad generated Fire Alarm (pressing the <A> & <B> together) can be assigned to an Output or multiple Outputs.
This can be used to operate an audible or visual alarm connected to the Output.
KEYPAD MEDICAL ALARM to OUTPUT
KEYPAD MEDICAL ALARM (<B> & <CHIME>) to OUTPUT -
P86E 1-32E Value = 01-32 for Outputs 1-32
Option 01 = Output 1 - Option 32 = Output 32
A Keypad generated Medical Alarm (pressing the <B> & <CHIME> together) can be assigned to an Output or
multiple Outputs. This can be used to operate an audible or visual alarm connected to the Output.
KEYPAD DURESS ALARM to OUTPUT
KEYPAD DURESS ALARM to OUTPUT -
P87E 1-32E Value = 01-32 for Outputs 1-32
Option 01 = Output 1 - Option 32 = Output 32
A Keypad generated Duress Alarm (see P25E2E) can be assigned to an Output or multiple Outputs. This can be
used to operate an audible or visual alarm connected to the Output. A Duress alarm is created when the alarm is
Disarmed with the Duress digit preceding a valid User Code.
KEYPAD TAMPER SWITCH ALARM to OUTPUT
KEYPAD TAMPER SWITCH ALARM to OUTPUT -
P88E 1-32E Value = 01-32 for Outputs 1-32
Option 01 = Output 1 - Option 32 = Output 32
If the keypad has a Tamper Switch fitted and this switch is activated, the Tamper Alarm can be assigned to an Output
or multiple Outputs. This can be used to operate an audible or visual alarm connected to the Output.
KEYPAD WRONG CODE ALARM to OUTPUT
KEYPAD WRONG CODE ALARM to OUTPUT -
P89E 1-32E Value = 01-32 for Outputs 1-32
Option 01 = Output 1 - Option 32 = Output 32
If someone is attempting disarm the alarm by trying various code combinations and they enter in 4 wrong codes the
panel will go into a “Wrong Code” tamper alarm. The Alarm can be assigned to an Output or multiple Outputs. This
can be used to operate an audible or visual alarm connected to the Output. A correct code entry will reset the tamper
alarm.
MANUAL PANIC ALARM BEEPS TO KEYPAD
MANUAL PANIC ALARM BEEPS TO KEYPAD -
P90E 1-32E Value = 01-32 for Keypads 1-32
Option 01 = Keypad 1 - Option 32 = Keypad 32
When a keypad Panic Alarm is generated, the alarm can be silent or it can operate the buzzer in the keypad.