Page 58
Option 1 - Can Arm if Zone is not Ready
Option 2 - Will Send Multiple Reports to Dialler
Option 3 - Zone is Monitored for Inactivity
Option 4 - Zone is on Soak Test
Option 5 - Report using the highest assigned Area
Option 6 - Zone will Not Report 24 hour Alarms via Dialler
Option 7 - Pulse Output on Kiss-off Following a Zone Alarm
Option 8 - Exit Terminator Zone
Option 1
Can Arm if Zone is not Ready
- If this option is turned on, plus Options 7 or 8 are on at P45E (cannot
Arm if zones not sealed/Ready), this zone can be unsealed and the panel can still be armed. This
option allows the panel to still be armed if a low security zone is unsealed yet still stopping arming if a
high security zone is unsealed.
Option 2
Will Send Multiple Reports to Dialler
- If this option is turned on, a zone will send an alarm report to
the monitoring station every time it is activated. If the option is turned off, the zone can only send one
alarm report per armed cycle.
Option 3
Zone is Monitored for Inactivity
- If this option is on the zone will be checked to see that it operates
during the disarmed state. If it is not operated within the time set at P163E a “Sensor-watch” alarm will
be generated. This feature is designed to detect a faulty zone that is not operating normally or one that
has had it’s detection area blocked. If a detector has this option turned on and it doesn’t operate when
disarmed, the timer at location P163E will start to count down. The timer is stopped when the area
assigned to the zone is armed and resumes with the saved value when disarmed again. The timer is
reset back to the original value every time the zone operates while disarmed.
Option 4
Zone is a Soak Test Zone
- If a zone is suspected of being faulty and is causing false alarms, you can
turn it into a Soak Test Zone and it will still be monitored for alarms when armed but it will not cause
the sirens to sound or report to the dialler. The Soak Test zone will still be logged in the event memory
however so it is possible to check the activity of the zone, via the memory, and after a suitable period
of no alarms it can be re-instated as part of the alarm by removing the Soak Test option.
Option 5
Report using the highest assigned Area -
If a zone is assigned to more than one area and it is
programmed to report activity via the dialler this option selects whether the panel will use the lowest or
the highest assigned area for reporting. If a value of 0 is programmed at address P147E for the zone
and this option is turned OFF the zone will report using the lowest assigned area. If P147E is 0 and
this option is ON the zone will report using the highest assigned area.
Option 6
Zone will Not Report 24 Hour Alarms via Dialler
- If this option is turned on and the zone is set as a
24 Hour type, when an alarm is generated, the alarm will not be transmitted to the monitoring station
via the dialler.
Option 7
Pulse Output on Kiss-off Following a Zone Alarm
- If this option is turned on, when an alarm is
reported to monitoring and is kissed off, any Output with Option 4 ON at P36E will pulse for 2 seconds.
Option 8
Exit Terminator Zone
- If this option is on, when the zone unseals during the exit delay time and then
seals again the panel will cancel any remaining exit delay time and arm in 3 seconds from the time the
zone was sealed. The zone can also be left unsealed at the time of arming and will terminate the exit
delay 3 seconds after it is sealed. Once armed, the exit terminator zone will cause an alarm if unsealed
again (the alarm will be delayed if an entry delay is programmed (P144E), otherwise it will be instant).
ZONE OPTIONS D
ZONE OPTIONS D
- P6133E 1-64E Value 1-8
Option 1 - Zone is Excluded from Activity monitoring
Option 2 - Zone will hold off Arming until Sealed
Option 3 - “Security Interlock” zone
Option 1
Zone is Excluded from Activity monitoring
- If this option is turned on the zone cannot reset the
auto-arming activity timer (P4071E). If it is turned off the zone will reset the activity timer and delay
auto-arming if triggered.
Option 2
Zone will hold off Arming until Sealed
- If this option is turned on the zone will hold off arming due to
activity until the zone is sealed. This option can be used with a reed switch on a front door that when
left open will stop auto-arming on no activity until the door is closed. If this open is turned off the zone