Page 27
If the time-zone has just been programmed and should currently be active you will have to wait until the next
minute expires before the panel will update the time-zone status. You can see if the time-zone is active at location
P200E4E.
USER ACTIVATES DORMANT TIMEZONE
USER ACTIVATES TIMEZONE
- P1032E 1-2000E
Option 01 - 32 - User Activates Time Zone # 1-32
There are up to 32 Time Zones that can be programmed into the panel. A Time Zone can be programmed to be
Dormant unless activated by a User by turning on option 2 at P174E.
An example of how to use a Dormant Time Zone is when the front door of a building is set to automatically unlock
at the start of a Time Zone and lock when it ends. If the Time Zone is set to a dormant type the door will not
unlock until a valid user has accessed the building. Once the valid user has accessed the building the door will
unlock and remain unlocked until the Time Zone ends. Valid users are selected at the new program location
P1032E. A user is assigned to a Time Zone at P1032E and if that Time Zone is set to be dormant it will not start
until the user accesses the building.
USER to KEYPAD ASSIGNMENT
USER to KEYPAD ASSIGNMENT
- P10E 1-2000E
Option 01 - 32 User will work at Keypad # 1-32
Any user can be assigned to only operate at certain Keypads. This option controls whether a code or access tag
User can Arm/Disarm from certain keypads. This option does not restrict users from operating outputs from a
particular keypad (this is done at locations P82E & P83E).
RADIO PENDANT PANIC BEEPS to KEYPAD
RADIO PENDANT PANIC BEEPS to KEYPAD
- P11E 101-2000E (NOTE: only Users 101-2000 can be Radio
Users)
Option 01 - 32 A Pendant Panic Alarm will Beep at Keypad # 1-32
If a Radio Pendant is programmed to create a Panic Alarm (see P8E), when the Panic Alarm is activated it can be
silent or it can sound the keypad buzzer. Each Radio Panic alarm created by a wireless User can be silent during
the Panic Alarm (option turned off) or can give an audible indication of the Alarm at a keypad (option turned on).
USER can turn an OUTPUT ON
USER can turn an OUTPUT ON
- P13E 1-2000E
Option 01 - 32 User can turn ON Output # 1-32
Any user can be allowed to turn an Output ON. This Function will allow Users (Code, Tag/Card or Radio Users) to
turn ON an assigned Output. Once an Output is turned ON by a User, the Output can turn OFF again
automatically if a reset time is assigned to the Output. If no reset time is assigned to the output (Address P40E)
the output must then be turned off by a User with the same output assigned at P14E.
USER can turn an OUTPUT OFF
USER can turn an OUTPUT OFF
- P14E 1-2000E
Option 01 - 32 User can turn OFF Output # 1-32
Any user can be allowed to turn an Output OFF. This Function will allow Users (Code, Tag/Card or Radio Users)
to turn OFF an assigned Output that has previously been turned on by a user with option P13E assigned.
RADIO PENDANT PANIC ALARM to OUTPUT
RADIO PENDANT PANIC ALARM to OUTPUT
- P15E 101-2000E (NOTE: only Users 101-2000 can be Radio
Users)
Option 01 - 32 A Pendant Panic Alarm will Operate Output # 1-32