![Crow RUNNER 8/64 Installation & Programming Manual Download Page 38](http://html1.mh-extra.com/html/crow/runner-8-64/runner-8-64_installation-and-programming-manual_2689361038.webp)
Page 38
Option 2
Pulse Output every 5 seconds when Disarmed
- This option will cause the Output to pulse every 5
seconds when the panel is disarmed. The pulse time is linked to the Output Pulse time (P39E).
Option 3
Pulse Output on Kiss-off Following Arming
- This option will cause the Output to pulse for 2
seconds when the panel is armed and the message has been kissed off by the monitoring company.
The pulse time is linked to the Output Pulse time (P39E) which is defaulted to 2 seconds.
Option 4
Pulse Output on Kiss-off Following a Zone Alarm
- This option will cause the Output to pulse for 2
seconds when a zone has gone into alarm and has been kissed off by the monitoring company. The
zone must have option 7 turned ON at P124E. The pulse time is linked to the Output Pulse time
(P39E) which is defaulted to 2 seconds.
Option 5
Output Disabled when P25E3E timer is running
- This option will cause the Output to be disabled
when the dialler reporting delay is active. It is designed to keep external audible alarms silent when
the dial delay is active (allowing internal alarms to warn that the alarm will be reported to monitoring if
not unset) but if the alarm hasn’t been reset before the timer expires the external alarm will sound
Option 6
Output Indicates In-coming phone call
- If this option is On it will cause the Output to pulse in time
with an in-coming telephone call. It is designed to be used as a remote call (ring detect) indicator.
Option 7
Play Doorbell tone on a Chime Zone trigger
- If this option is turned on and a Chime zone alarm is
triggered on output 1 or 2 the panel will play a Doorbell tone to the output. If the option is turned off a
Chime zone alarm will play a single tone to output 1 or 2. The volume setting at P33E applies to
these tones when played to output 1 or 2.
Option 8
IP Fail (Timed)
- If IP Monitoring is being used and the panel fails to report a signal or a poll it will
enter a “Comm Failure” state and the output will turn on. The output MUST have a reset time
programmed at P40E as it needs a reset time to allow the output to reset after being triggered.
OUTPUT OPTIONS “D”
OUTPUT OPTIONS “D” -
P37E 01-32E
Option 1 - Siren Driver to Output (applies to O/P 1&2 only, requires an 8
Ώ
speaker)
Option 2 - Output Chime Timer is in Minutes
Option 3 - Output “Silenced” for 10 seconds on key-press
Option 4 - Turn Output OFF during Two Way Voice Mode
Option 5 - Spare
Option 6 - Pulse output when exit delay to Output (P65E) is running
Option 7 - Spare
Option 8 - Output Monitored (applies to O/P 1&2 only)
Option 1
Siren Driver to Output
- This option is used to assign a Modulated Siren tone to an Output. The
option only applies to Outputs 1 and 2. For the modulated siren tone to work correctly, an 8
Ώ
speaker
must be connected to the output concerned. The siren tones will vary depending on the trigger. For
example, if the trigger is a walk test pulse or wireless arm/disarm chirp the tone will be a single tone.
If the trigger is a chime zone the tone will be a door bell chime. If the trigger is an alarm (normal or 24
hour) the tone will be a siren sound. The volume of the various tones can be adjusted at P33E. If this
option is turned on for Outputs 1 and/or 2 it will also inhibit the Output during two way voice mode
(see option 4 below).
Option 2
Output Chime Timer is in Minutes
- The default setting for the Output Chime time (P41E) is in
1/10th seconds. If longer times are required, this option turns chime times into minutes (eg 1-9999
minutes).
Option 3
Output “Silenced” for 10 seconds on key-press
- When the alarm is Armed and activated it can
be difficult sometimes to turn the alarm off because you are unable to hear the beeps as you enter
your code at the keypad. If this option is turned on the selected output/s will silence (turn off) for 10
seconds on the first button press at any keypad. This should allow easy Disarming of the alarm by a
valid User. If the alarm is not turned off within the 10 seconds, the outputs will turn on again. This
function will only work once during an Armed cycle and the panel must be Disarmed before it will
work again.
Option 4
Turn Output OFF during Two Way Voice Mode -
If the panel has a full duplex two way voice board
fitted and the settings at P175E2E option 8 and P183E option 5 are set to allow full duplex mode, any
outputs with this option turned on will be disabled while two way voice is operational. This is to
ensure that local sirens do not interfere with the two way voice audio signal.