Page 61
selecting Type 32 allows the panel to correctly recognize the alarm, tamper and battery low signal from
the device. The supervisory signal sent by the device is ignored in this mode.
Type 33
Visonic Powercode (supervised) -
If the Visonic Powercode range of radio PIR or reed switch are
used on the panel selecting Type 33 allows the panel to correctly recognize the alarm, tamper & battery
low signals from the devices as well as the open/close signal from the reed switch. Selecting this option
also starts the supervise timer (P25E4E). The supervise timer is constantly being reset while valid
supervisory signals are being received from the detector. If no supervise signals are received from the
PIR within the supervise timer value a supervised alarm is generated.
ARMED ZONE ALARMS to OUTPUT
ARMED ZONE ALARMS to OUTPUT -
P128E 1-64E Value = 01-32 for Outputs 1-32
Option 01 = Output 1 - Option 32 = Output 32
If an Area is Armed and a zone assigned to that Area activates, the zone can trigger selected Outputs for local alarm
signalling. This location assigns Zones to Outputs for alarms that occur when in the Full Armed State.
STAY MODE ZONE ALARMS to OUTPUT
STAY MODE ZONE ALARMS to OUTPUT -
P129E 1-64E Value = 01-32 for Outputs 1-32
Option 01 = Output 1 - Option 32 = Output 32
If an Area has Stay Mode Armed and a zone assigned to that Area activates, the zone can trigger selected Outputs
for local alarm signalling. This location assigns Zones to Outputs for alarms that occur when Stay Mode is Armed.
24 HOUR ZONE ALARMS to OUTPUT
24 HOUR ZONE ALARMS to OUTPUT -
P130E 1-64E Value = 01-32 for Outputs 1-32
Option 01 = Output 1 - Option 32 = Output 32
If a zone is programmed as a 24 Hour type and it activates, the zone can trigger selected Outputs for local alarm
signalling. If the zone is a standard 24 hour type (P123E option 3 on) the output will turn for the full reset time, if it is
an Auto-reset type (P123E option 4 on) the output will either turn off when the reset time expires or if the input clears
and if it is a Fire type (P123E option 5 on) the output will pulse at a rate equal to the pulse time for that output.
CHIME ZONE ALARMS to OUTPUT
CHIME ZONE ALARMS to OUTPUT -
P131E 1-64E Value = 01-32 for Outputs 1-32
Option 01 = Output 1 - Option 32 = Output 32
If a zone is programmed as a Chime zone (P123E option 7 or 8 on) and it activates, the zone can trigger selected
Outputs for local alarm signalling. The output will operate for the Chime to Output time at location P41E. The zone
must clear before the output can be activated again.
ZONE TAMPER ALARMS to OUTPUT
ZONE TAMPER ALARMS to OUTPUT -
P132E 1-64E Value = 01-32 for Outputs 1-32
Option 01 = Output 1 - Option 32 = Output 32
If a hardwired zone is programmed to allow tamper monitoring (P125E types 12,13 & 14), or the zone is a radio
detector with tamper, the zone tamper can trigger selected Outputs for local alarm signalling.
ARMED ZONE ALARM BEEPS TO KEYPAD
ARMED ZONE ALARM BEEPS TO KEYPAD -
P134E 1-64E Value = 01-32 for Keypads 1-32
Option 01 = Keypad 1 - Option 32 = Keypad 32
If an Area is Armed and a zone assigned to that Area activates, the zone can sound the buzzer at selected keypad.
This location assigns zone alarm beep to a keypad for alarms that occur when in the Full Armed State.
STAY MODE ZONE ALARM BEEPS TO KEYPAD
STAY MODE ZONE ALARM BEEPS TO KEYPAD -
P135E 1-64E Value = 01-32 for Keypads 1-32