Page 47
buttons are pressed simultaneously.
NOTE: If a keypad Fire alarm is generated it will create a separate
Fire Alarm for every area assigned to the keypad at Address P71E. To clear the alarm fully the Fire
alarm must be cleared for all areas so the code used to reset the alarm must be assigned to the same
areas (P3E) as the keypad (P71E).
Option 7
<B> + <CHIME> Medical Alarm Enabled
- This option enables a Medical Alarm to be created when
the <B> + <CHIME> buttons are pressed simultaneously.
NOTE: If a keypad Medical alarm is generated
it will create a separate Medical Alarm for every area assigned to the keypad at Address P71E. To clear
the alarm fully the Medical alarm must be cleared for all areas so the code used to reset the alarm must
be assigned to the same areas (P3E) as the keypad (P71E).
Option 8
Stay Armed Beep to Keypad
- If this option is turned on the keypad will give three short beeps when
Stay Mode is armed. It is designed to be used when stay mode exit delay beeps (P59E) are turned off to
provide an audible indication that Stay mode is now armed from the selected keypad.
KEYPAD OPTIONS C
KEYPAD OPTIONS C
- P5070E 1-32E
Option 1 - Enable Away Disarming at keypad
Option 2 - Enable Stay Disarming at keypad
Option 1
Enable Away Disarming at keypad
- This option works in conjunction with option 3 at address P72E.
Normally a user or access tag can arm and disarm at all keypads if programmed to do so however using
option 3 at P72E the away arming can be disabled at any of the 32 keypads. At this address the
disarming of away mode can be disabled. Between P72E option 3 and this program option an arm only
and a disarm only keypad can be set up.
Option 2
Enable Stay Disarming at keypad
- This option works in conjunction with option 4 at address P72E.
Normally a user or access tag can Stay arm and disarm at all keypads if programmed to do so however
using option 4 at P72E the stay arming can be disabled at any of the 32 keypads. At this address the
disarming of stay mode can be disabled. Between P72E option 4 and this program option a stay arm
only and a stay disarm only keypad can be set up.
KEYPAD SYSTEM BEEPS & LED OPTIONS
KEYPAD SYSTEM BEEPS & LED OPTIONS
- P73E 1-32E
Option 1 - Mains Fail Beeps Keypad Buzzer
Option 2 - Fuse Fail Beeps Keypad Buzzer
Option 3 - Battery Low Beeps Keypad Buzzer
Option 4 - Telephone Line Fail Beeps Keypad Buzzer
Option 5 - System Tamper Beeps Keypad Buzzer
Option 6 - Receiver Fail Beeps Keypad Buzzer
Option 7 - Turn Off Keypad LED’s and Backlighting when Armed
Option 8 - Turn Off LCD & Keypad Backlighting on Mains Fail
Option 1
Mains Fail Beeps Keypad Buzzer
- If this option is on a Mains Failure will cause the keypad buzzer to
sound continuously. The continuous beep will automatically clear when the Mains returns to normal or it
can be silenced by pressing the <ENTER> button on the keypad.
Option 2
Fuse Fail Beeps Keypad Buzzer
- If this option is on a Fuse Failure (12v DC output short) will cause
the keypad buzzer to sound continuously. The continuous beep will automatically clear when the short is
removed and the fuse returns to normal or it can be silenced by pressing the <ENTER> button on the
keypad.
Option 3
Battery Low Beeps Keypad Buzzer
- If this option is on a Panel Battery Low will cause the keypad
buzzer to sound continuously. The continuous beep will automatically clear when the battery returns to
normal or it can be silenced by pressing the <ENTER> button on the keypad.
Option 4
Telephone Line Fail Beeps Keypad Buzzer
- If this option is on a Telephone Line Failure will cause
the keypad buzzer to sound continuously. The continuous beep will automatically clear when the
Telephone Line returns to normal or it can be silenced by pressing the <ENTER> button on the keypad.
Option 5
System Tamper Beeps Keypad Buzzer
- If this option is on a Panel Tamper Alarm will cause the
keypad buzzer to sound continuously. The Alarm must then be cleared by entering in a valid code at the