Page 26
RADIO USER TYPE
RADIO USER TYPE
- P7E 101-2000E (NOTE: only Users 101-2000 can be Radio Users)
Option 0 - Generic (General Pendant Type)
Option 1 - Crow Freewave Pendant
Option 21 - Ness Pendant
Option 0
Generic Type
- If a Radio Pendant has no special functions and does not send a battery low signal
it is a Generic type 0.
Option 1
Crow Freewave Type
- If a Crow Freewave Radio Pendant is being used set the type to 1. When
the pendant detects a battery low it will send a signal to the panel.
Option 21
Ness Type
- If a Ness Radio Pendant is being used set the type to 21. When the pendant detects a
battery low it will send a signal to the panel.
RADIO USER PRIVILEGES
RADIO USER PRIVILEGES
- P8E 101-2000E (NOTE: only Users 101-2000 can be Radio Users)
Option 1 - Pendant can Disarm at All Times
Option 2 - Pendant will cause an Immediate Panic Alarm
Option 3 - Pendant will cause a Delayed Panic Alarm (1.5 sec)
Option 4 - Pendant only works during entry delay
Option 5 - This User is a dedicated Duress Code
Option 6-8 - Spare
Option 1
Pendant can Disarm at All Times
- If a Radio Pendant has option 1 on, they can Disarm the alarm
at any time. If this option is off, the pendant cannot disarm if the panel is in alarm state.
Option 2
Pendant will cause an Immediate Panic Alarm
- If a Radio Pendant has option 2 on, a Panic
Alarm will be generated immediately the button is pressed.
Option 3
Pendant will cause a Delayed Panic Alarm
- If a Radio Pendant has option 3 on, a Panic Alarm
will be generated if the button is pressed for longer that 1.5 seconds. If the button is released before
the time expires, no Panic Alarm will be generated.
Option 4
Pendant only works during entry delay
- If a Radio Pendant has option 4 on, the pendant can
only disarm the alarm during the entry delay time. This means that authorised radio key users must
enter the building and trigger the entry delay before they can disarm the alarm.
Option 5
This User is a dedicated Duress Code
- If a User Code has option 5 on (restricted to Users 21-
100 only), this code should be used as a dedicated Duress code. It should not be used for daily
disarming of the alarm but used when disarming under Duress.
TIMEZONE ASSIGNED to a USER
TIMEZONE ASSIGNED to a USER
- P9E 1-2000E
Option 01 - 32 - User Controlled by Time Zone # 1-32
There are up to 32 Time Zones that can be programmed into the panel. A Time Zone consists of a Start and
Stop time plus the Days of the Week that the Time Zone is active. By turning on Options 01-32 (assigning any
combination of Time Zones 1-32) to a particular User, that user will only operate if the Time Zone/s assigned is/
are active.
For example, if Time Zone #1 had a start time of 0800 and a stop time of 1700 and active days of 2-6 (Monday-
Friday), a User with Time Zone 1 assigned can only be used between the hours of 0800-1700 from Monday to
Friday. Outside these hours the User Code will not operate.
More than one Time Zone can be assigned to a User. Using the above example for TZ#1 and now assuming
Time Zone #2 is set to 0900-1200 on day 7 (Saturday), by assigning both TZ1 & 2 to a User will now mean their
code is active during weekdays from 0800-1700 plus they are also able to use their code on Saturdays between
the hours of 0900-1200.