80
minutes. The inverter will scan the maximum power point in
the MPPT range, according to the following condition:
While in Parallel mode, the total input power is lower than 90%
of the active power.
While in Independent mode (3 MPPTs), the input power
must be lower than 75% of the rated power for each MPPT
tracker.
Once this MPPT scan function is activated on LCD, it will
search the maximum power point at a voltage step of 5V in
the MPPT range for full load, and retrieve the maximum
power point.