Scanner Operation - Panel and Indicators
4-6
Scanner Ready (startup – phase 4)
When the Wait LED turns off, and only the Power LED is on and lights
green, self-adjustment is completed and the scanner is ready to scan.
Green Power LED flashing
The green power LED will flash just before the scanner
automatically powers off because its defined automatic Sleep
time (in WIDEsystem) has been reached in the timer.
If you are still using the scanner and want to cancel the timer
controlled Sleep mode, press the power key until the LED
stops blinking.
You can at any time disable or change timer settings in
WIDEsystem (see WIDEsystem on-line help for details).
Wait LED Flashes - Self-Adjustment required but not possible
If the Wait LED flashes (and the Diagnostics LED is off) the scanner
needs to run Self-Adjustment but cannot. Self-Adjustment is
necessary for maintaining optimal and stabile internal conditions.
To solve this, any original in the scanner should be removed, and the
pressure-platen should be set to the
Normal
position (i.e., not a thick
media setting). A scan may be issued, but the quality will be
compromised. When Self-Adjustment is again possible, the Wait LED
stops flashing, but continues to be on until Self-Adjustment is
completed. The scanner should be left alone while Self-adjustment is
running.
During Calibration – Wait LED lights
This is normal. The Wait LED is on during Calibration to indicate that
the original should not be removed or moved during the Calibration
procedure.
All panel input is prevented during basic calibration.