1
Securely bolt the HTC control to the left side of the floor stand.
Use the supplied
locking fasteners to securely mount the HTC control center to the floor stand to
prevent vibration-induced loosening.
NOTE:
If, by using your own provisions, you change the mounting arrangement of the control center to a
wall mount unit, it must be mounted six (6) inches {152.4 mm} off of the wall to provide clearance for the
heat sink.
Installing the HTC Control
(continued)
(Models HTC 180 and 270)
CAUTION:
You are responsible for the structural integrity of this installation.
1
Move the control center into
its final location for opera-
tion
(see figure to the right).
The control center must be
positioned close enough to the
hopper to allow connection of
the RTD temperature probe.
The control center can be
mounted to a wall, the hopper
frame or a floor stand with
customer supplied provisions.
NOTE:
If, by using your own provisions, you change the mounting arrangement of the control center to a
wall mount unit, it must be mounted six (6) inches {152.4 mm} off of the wall to provide clearance for the
heat sink.
NOTE:
If the lengths of the
process and process
protection RTD wiring are
too short for your installation,
contact Conair Parts Depart -
ment (800.458.1960) to
purchase extension cables.
From outside the United States,
call (814.437.6861).
NOTE:
If using a GasTrac for
the drying system heat source,
see
“Installing the Hopper
Cone Section”
HTC Control Center
(Free-Standing)
HTC Control
Center