2-6
I
Hopper Installation Guide
IMPORTANT:
Reference your system
layout drawings for the
correct cyclone bracket
bolt pattern usage
before
it is installed.
IMPORTANT:
The optional cyclone
is designed to be
connected to the return
air circuit of the hopper,
then connected to an
optional dust collector
or to the dryer’s air
inlet.
Installing the Cyclone Dust Collector
(optional)
To install the cyclone to the hopper:
1
Determine if the cyclone is a right
or left mounted version.
This can be
determined by the location of the air inlet
on the cyclone. If the inlet is on the right
side, the cyclone will be right mounted
and if it’s in the left side, it will be left
mounted.
2
Start to assemble the
cyclone mounting
bracket, elbow,
hose and clamps.
NOTE:
The elbow,
hose and clamps can be
assembled to the cyclone
assembly before or after
cyclone installation on to
the hopper.
3
Remove the hose from the
assembly for installation.
4
Measure the distance from
the hopper lid (top of the
hopper) to the top of the flange
of the next section below.
(Continued)