95
REACTION TYPE
This section is enabled only for Burglary type zones. For all other types of zone, this zone is made inaccessible. The reaction of a zone, in the event
of violation, derives from the fact that the following conditions must be met:
• Instant:
if this option is selected, when the zone is violated, not excluded, not in test and the areas to which it belongs are Activated, it
immediately generates the events (specified using the Alarm type menu): Zone alarm, Area alarm.
The testing and instant burglar
zones do not generate failed activation faults and do not end the output times.
• Delayed input 1:
if this option is selected, when the zone is violated, not excluded, not in test and the areas to which it belongs are Activated,
it starts the longer Input time 1 for the Activated Areas to which it belongs. During the input time, the enabled keypads will
emit an alert sound. If at the end of Input time 1 the areas to which the zone belongs have still not been deactivated, or the
zone is violated when Input time 1 has elapsed, the events are generated (as for an Instant type zone).
Suggestion: if the
layout necessitates walking through the protected spaces to deactivate the alarm system areas, the first zone to be
violated should be of Delayed input type.
• Delayed input 2:
as above, but with reference to area timer Input 2.
• Input path:
If this option is selected, when the zone is violated, not excluded, not in test, the areas to which it belongs are Activated and there is
no input time in progress, it generates an alarm. During the input time, the enabled keypads will emit an alert sound. If at the end of
Input time the areas to which the zone belongs have still not been deactivated, or the zone is violated when Input time has elapsed,
the events are generated (as for an Instant type zone). The violation of an Input path zone during the Input time for its Area does not
generate any event.
Suggestion: the zones to be passed through to reach the point at which it is possible to deactivate the
areas to which the zones belong should be configured as an input path.
• Delayed in output:
if this option is selected, violation of the zone during an Output time does not cause any event to be generated. If the zone is
violated in the absence of an Output time, it behaves as zone programming, reaction type: Instant or Delayed.
Suggestion:
the zones that need to be passed through after activation to exit the premises protected by the control panel
should be configured as Delayed in output.
• Last output:
During the Output time, the enabled control devices will beep. If the zone is violated and the output time is not yet ended, the Last
Output Time Timer replaces the value remaining for the Area Output Time. If the zone is violated when the Output time has elapsed
and the Areas to which the zone belongs are Activated, it behaves like zone programming, reaction type: Instant or Delayed.
Suggestion: the last zone that needs to be passed through after activation to exit the premises protected by the control
panel should be configured as last output.
√ must not be under testing
√ must not be excluded
√ the areas on which it depends for operation must be activated (only for burglary zones)
√ must not have reached the maximum number of alarm cycles if a limited number of cycles has been set.