16
• Quick activation:
activates the system (total / partial / scenarios) without asking for the user code (total or partial activations of the system will
not be allowed).
• Quick alarms:
sends alarms when a function key on the device is pressed.
• Display areas status:
authorises the device to display the status of the areas.
• Suspend when no mains power:
authorises the device to switch itself off in order to reduce battery consumption during a mains power outage.
• Tamper enabled:
enables device tamper.
• Display open zones:
authorises the device to display the open zones.
• Display chime zones
: authorises the device to display the open chime zones.
• Communication:
displays the channel with which to communicate with the control panel. Non settable parameter, read-only.
OPTIONS
CONFIGURATIONS PANEL
• Unlimited:
provides indications even with the system activated, without any time limits. If not selected, enables the Time box. To guarantee
conformity with standards CEI EN 50131-1 and 50131-3, this option must be disabled.
• Seconds:
if the Unlimited checkbox is not checked, this box establishes the duration, in seconds, of the display of information on the device
when the system is activated. The alarm memory signal on the control devices is always visible with the system off even if the system
status is not visible (e.g.: setting the display time of the system zero status).
• Unlimited:
allows you to generate infinite cycles of tamper alarms. If not selected, enables the Cycles box.
• Cycles:
if the Unlimited checkbox is not active, this box determines the number of tamper alarm cycles that the selected device can generate
within an activation cycle (from one activation to the next).
SYSTEM STATUS DISPLAY TIME
TAMPER ALARM CYCLES
• Unlimited:
allows you to generate infinite cycles of technical alarms. If not selected, enables the Cycles box.
• Cycles:
if the Unlimited checkbox is not active, this box determines the number of technical alarm cycles that the selected device can generate
within an activation cycle (from one activation to the next).
Keys available on touch devices Planux Manager, Minitouch, Icona ViP and Icona SBC.
See description
Px key functions on page 87
.
TECHNICAL ALARMS CYCLES (BUS/VOLTAGE LEVELS)
PX KEY FUNCTIONS
See description
Buzzer on page 88
.
See description
Send Message options on page. 89
.
BUZZER
SEND MESSAGE OPTIONS
NETWORK PARAMETERS
Keys available on touch devices Planux Manager, Minitouch, Icona ViP and Icona SBC.
See description
Function keys on page 88
.
FX KEY FUNCTIONS
Only if IP card expansion module Art. VEDOIP is present and configured.
• Device type:
this drop-down menu is used to select the device model from Planux Manager, Minitouch, PC Touch, Icona ViP and Icona SBC
. .
• IP address:
This box is for entering the network address that the device needs in order to be recognised and to communicate correctly on the
local network with the PAL/IP devices present. Bear in mind that the address must be part of the same network as the IP Module
in the control panel.
• Netmask:
This box is for entering the same Netmask address as used for the IP card expansion module connected to the control panel (se
e
“3.11.1 IP Options” on page 50
).
• Gateway:
This box is for entering the same Gateway address as used for the IP card expansion module connected to the control panel (se
e
“3.11.1 IP Options” on page 50
).
• Address acquisition mode:
displays the mode with which to acquire an IP address. Non settable parameter, read-only.
Configurations for viewing the cameras connected to PAL-IP modules Art. VEDOCCTV.
VIP OPTIONS
• Logic address:
field for entering a logic address for the device. The address must be a completely unique 8-digit number.
• Streaming video timeout:
determines the duration of a video call to the cameras. The same value must be set for the PAL-IP modules (see
"3.11.3 Pal/IP video module" on page 54
). If the values are different, the lower value is applied.