70
System parameters
Presence of expansions
GSM
PSTN
Network card (Ip)
Audio
Domotics
Intercom
Options
Forced activation Level 2 (anomalies)
RS485 bus speed
Language
Italiano
38400
Forced activation Level 2 (sabotage)
Activation with monitor fault (radio)
Activation with battery fault (radio)
Buzzer in partial
Sound in panic
Restore factory settings
Permanently enable installer code
Voice guide for telephone communicator
Total
Obbligo cambio codici di default
Failed activation fault
Enabling sabotage and fault tests for zones
3.14 SYSTEM PARAMETERS
Includes 6 independent checkboxes for enabling any expansions that may be present on the control panel. The check mark in the checkbox
enables the peripheral, which would not otherwise be considered, even if present. If you enable a peripheral that is not present, after transfer of the
programming to the control panel, system errors may be indicated.
• GSM:
refers to the GSM expansion card.
At least one of the options PSTN, GSM or IP must be enabled [Reg. 98]
• PSTN:
refers to the telephone interface supplied as standard. If it is enabled, but the telephone line is not present, an anomaly will be generated.
At least one of the options PSTN, GSM or IP must be enabled [Reg. 98]
• Network card (IP):
refers to the IP expansion card. If it is present and enabled, but there is no IP connection, an anomaly is generated.
• Audio:
refers to the messages expansion module. If enabled but not present, it generates an anomaly.
At least one of the options PSTN, GSM
or IP must be enabled [Reg. 98]
• Domotics:
not implemented.
• Intercom:
not implemented.
PRESENCE OF EXPANSIONS
• Language:
drop-down menu, allows you to set the user interface language (on-screen menus and messages).
• RS485 bus speed:
drop-down menu, allows you to select the speed of the RS485 communication bus, from between 9600 and 115200 baud.
The standard is 38400 baud.
• Forced activation Level 2 (faults):
checkbox; if selected, allows a user to force an activation in the presence of anomalies. This operation
degrades the performance of the control panel at grade 2. If deselected, allows the user to perform only the
following forced activations (in presence of faults):
OPTIONS
• Faults
• Zone fault
• Radio control fault
• Power supply unit battery fault
Faults:
• No power supply unit network
• Radio control battery fault
• Camera fault
• Remote communication failed
• Robbery zone fault
• Failed activation fault
• IP Expansion fault from bus
Selected [Reg. 94]
• Forced activation level 2 (sabotage):
checkbox; if selected, allows a user to force an activation in the presence of sabotage. This operation
degrades the performance of the control panel at grade 2. If deselected, allows the user to perform only
the following forced activations (in presence of alarms/sabotage):
• Burglar
• H24
• Fire
• Panic
• Robbery
• Flooding
• Gas
• Medical
• All the alarms if the zones can be excluded
• Activations in the presence of sabotage
can be forced only by installers
Alarms:
Sabotage:
Selected [Reg. 95] NOT selected [Incert]