96
ATTRIBUTES
• Excluded:
the zone with this attribute will be excluded, it will not generate the Zone alarm event. Anomaly and sabotage conditions will be indicated.
• Cannot Exclude:
the zones with this attribute cannot be forced if they are not ready for activation during the system activation process (alarm,
sabotage, fault).
• Chime:
the zone with this attribute, generates a chime event if the area to which it belongs is Deactivated. The enabled control devices will beep,
otherwise (Area Activated) it will behave as specified via the Reaction type parameter.
• Test:
the zone with this attribute, is operational with all effects, however it does not cause the alarm event but records the event in the EVENTS
LOG. This attribute allows monitoring of a zone without causing alarm signals. The testing and instant burglar zones do not generate failed
activation faults and do not end the output times.
• Auto excludable:
the zone with this attribute will be excluded automatically if violated during activation of the Area to which it belongs. The next time
the Area to which the zone belongs is deactivated, the zone will be activated automatically. The Auto-excludable attribute also
affects zones with Reaction type: Output Time. The zone will be automatically excluded when Output Time for the area to which
it belongs has elapsed.
NOT selected [Reg. 38]
• Auto excludable with reset:
the zone with this attribute will be excluded automatically if violated during activation of the Area to which it belongs. The
zone will be activated automatically when it reverts to standby, behaving as specified via the Reaction type parameter.
The Auto-excludable attribute also affects zones with Reaction type: Output Time. The zone will be automatically
excluded when Output Time for the area to which it belongs has elapsed.
NOT selected [Reg. 39]
• Output delay with termination:
the zone with this attribute, if violated during Output Time for the area to which it belongs, causes the area Output
Time to be terminated, when the area reverts to standby and is ready for activation.
• Partial 1:
the zone with this attribute is activated if the areas to which it belongs are activated in Partial 1, Partial 1+2 and in Total.
• Partial 2:
the zone with this attribute is activated if the areas to which it belongs are activated in Partial 2, Partial 1+2 and in Total.
• Delayed on partial activation
Enable output delay on partial activation:
if this option is selected, the zone will be activated following the output delay also for partial
activations (P1, P2, P1+P2).
• Delayed and assess ready activation:
if this option is selected, if the zone is violated at the moment of activation, forced activation of the system
will be requested. In this condition the system will be forced and the zone will be active and will behave as
specified via the Reaction type parameter.
• Display during input/output:
if this option is selected, the open zone will be displayed also during the input/output time.
• Alarm verified:
if selected and it is a burglary type zone, the verified alarm is generated immediately without having confirmation from another zone.
COMMAND TYPE
This section is for setting the type of command (or commands) that can be generated by the zone.
• Pulse Act/Deact:
if selected, violation of the zone inverts the activation or deactivation status of the areas to which it is associated. The return
of the zone to standby status will have no effect.
• Bistable Act/Deact:
if selected, violation of the zone activates the areas to which it is associated. The return to standby status deactivates them.
• Activation only:
if selected, violation of the zone activates the areas to which it is associated. The return of the zone to standby status will have
no effect.
• Deactivation only:
if selected, violation of the zone deactivates the areas to which it is associated. The return of the zone to standby status will
have no effect.
• Reset Area:
if selected, violation of the zone resets the areas associated with the zone to activation conditions.
• Reset system:
if selected, violation of the zone resets the system alarms.
• Cancel telephone calls:
if selected, violation of the zone blocks all outgoing phone calls.
• Extended not ready for activation:
if selected, violation of the zone prevents activation of the associated areas.
• Extended ready for activation:
if selected, violation of the zone permits activation of the associated areas.
Summary of Contents for VEDO 2.6 Series