22
Status
Activate
Absent
Absent
Absent
1
2
3
4
ID Description
Expansion 1
Expansion 2
Expansion 3
Expansion 4
Area 2
Area 3
Area 4
Area 5
Area 6
Area 7
Area 8
Area 1
Display tamper
Display technical alarms
Area
Tamper alarm cycles
Unlimited
Cycles
0
Technical alarms cycles (bus / voltage levels)
Unlimited
Cycles
0
8 input/output expansions
Send message options
Send detailed events SMS
Send Email messages
Send digital communication
Send notification to App
Terminals
1
2
3
4
In
In
In
In
Absent
Absent
Absent
Absent
5
6
7
8
Expansion 5
Expansion 6
Expansion 7
Expansion 8
Absent
Absent
Absent
Absent
9
10
11
12
Expansion 9
Expansion 10
Expansion 11
Expansion 12
5
In
6
In
7
In
8
In
3.2 EXPANSIONS ON BUS
3.2.1 8 input/output expansions
This section is for configuring the parameters of the input/output expansions. These are bus expansions which provide 8 configurable inputs (or
open-collector outputs).
See description
Status / ID / Description on page 87
.
STATUS / ID / DESCRIPTION
STATUS/DESCRIPTION PANEL
Column showing the names of the areas in the system. To edit names, see
"3.6 Areas" on page 37
.
Allows you to choose to which areas the Tamper alarm generated by the device is sent.
At least one area to which the tamper alarms generated by
the device are to be signalled must be assigned to each active device [Reg. 5]
Allows you to choose to which areas the technical alarms generated by the device are sent.
At least one area to which the technical alarms
generated by the device are to be signalled must be assigned to each active device [Reg. 6]
The expansion devices provide 8 terminals as standard; they can be configured as inputs or open collector outputs. In this box, you can set whether
each of the terminals is to be used as an input or an output. By clicking the terminal icon you can switch the selection from In to Out and vice-versa.
• Unlimited:
allows you to generate infinite cycles of tamper alarms. If not selected, enables the Cycles box.
Selected [Reg. 12]
• Cycles:
if the Unlimited checkbox is not active, this box determines the number of tamper alarm cycles that the selected device can generate
within an activation cycle (from one activation to the next).
• Unlimited:
allows you to generate infinite cycles of technical alarms. If not selected, enables the Cycles box.
Selected [Reg. 13]
• Cycles:
if the Unlimited checkbox is not active, this box determines the number of technical alarm cycles that the selected device can generate
within an activation cycle (from one activation to the next).
AREAS PANEL
AREA
DISPLAY TAMPER
DISPLAY TECHNICAL ALARMS
TERMINALS
TAMPER ALARM CYCLES
TECHNICAL ALARMS CYCLES (BUS/VOLTAGE LEVELS)
See description
Send Message options on page. 89
.
All active devices must permit the control panel to send notification to the digital communicator for events generated by the device itself [Reg. 16].
SEND MESSAGE OPTIONS
CONFIGURATIONS PANEL