85
5.3.22 Service voice messages
x: from 1 to 6
Indices
Parameters
Configurations necessary to guarantee
Grade 2 certification
1.1.1.36.x.1
Text
The system address field must be
completed
5.3.23 Timer Types
Vedo10
x: from 1 to 4 /
Vedo34
x: from 1 to 8 /
Vedo68
x: from 1 to 8 /
Vedo200
x: from 1 to 32
Vedo10
y: from 1 to 4 /
Vedo34
y: from 1 to 16 /
Vedo68
y: from 1 to 16 /
Vedo200
y: from 1 to 32
TIMER TYPE SCHEDULES
Indices
Parameters
Configurations necessary to guarantee
Grade 2 certification
1.1.1.37.x.2.y.1
Time ON1
Timer 4 completed*
1.1.1.37.x.2.y.2
Time OFF1
Timer 4 completed*
*
Timer 4 completed and linked with the two regular general events
5.3.24 Timer Model
Vedo10/Vedo34/Vedo68
x: from 1 to 30 /
Vedo200
x: from 1 to 60
Indices
Parameters
Configurations necessary to guarantee
Grade 2 certification
1.1.1.39.x.1
Start day of week
Line 1 '*'
1.1.1.39.x.2
End day of week
Line 1 '*'
1.1.1.39.x.3
Start month
Line 1 '*'
1.1.1.39.x.4
End month
Line 1 '*'
1.1.1.39.x.5
Start date
Line 1 '*'
1.1.1.39.x.6
Selection
First line selected
1.1.1.39.x.7
End date
Line 1 '*'
1.1.1.39.x.8
Start year
Line 1 '*'
1.1.1.39.x.9
End year
Line 1 '*'
1.1.1.39.x.10
Timer Type
Line 1 'Timer 4'
5.3.25 System Parameters
Indices
Parameters
Configurations necessary to guarantee
Grade 2 certification
1.1.1.42.1.2
Customer Name
Fill in the field
1.1.1.42.1.3
System Address
Fill in the field
1.1.1.42.1.4
Network alarm delay
Max 60 seconds
1.1.1.42.1.5
Battery alarm delay
Max 5 minutes
1.1.1.42.1.14
Code errors
<=10
1.1.1.42.1.15
Reactivation time
Minimum 2 minutes
1.1.1.42.1.16
Alarm Cycles
Unlimited
1.1.1.42.1.17
Fault Cycles
Unlimited
1.1.1.42.1.18
Unlimited Alarm Cycles
Selected
1.1.1.42.1.19
Unlimited fault cycles
Selected
1.1.1.42.1.20
Device locked for incorrect
code
Selected
1.1.1.42.1.23
Activation with monitoring
fault
Selected
1.1.1.42.1.24
Forcing level 3 faults
Selected
1.1.1.42.1.25
Forcing level 3 sabotage
Selected
1.1.1.42.1.30
Installer always active
Deselected
1.1.1.42.1.32
IP card enable
At least one active of PSTN, GSM and IP
1.1.1.42.1.33
Audio control enable
Active if digital communicator or IP card is
not enabled
1.1.1.42.1.34
GSM card enable
At least one active of PSTN, GSM and IP
1.1.1.42.1.37
PSTN enable (on board)
At least one active of PSTN, GSM and IP
1.1.1.42.1.38
Failed activation fault enable
Selected
1.1.1.42.1.39
Enable test for fault and
zones sabotage
Deselected
1.1.1.42.1.42
Default codes change
mandatory
Selected
5.3.26 Events to be saved
x: from 1 to 2
Indices
Parameters
Configurations necessary to guarantee
Grade 2 certification
1.1.1.43.x.2
Zone Exclusion
Selected
1.1.1.43.x.3
Zone Isolation
Selected
1.1.1.43.x.4
Total ON
Only set selected
1.1.1.43.x.5
Partial 1 ON
Only set selected
1.1.1.43.x.6
Partial 2 ON
Only set selected
1.1.1.43.x.7
Effective activation
Only set selected
1.1.1.43.x.8
Deactivated
Only set selected
1.1.1.43.x.10
Burglar Alarm
Selected
1.1.1.43.x.11
24H Alarm
Selected
1.1.1.43.x.12
Fire Alarm
Selected
1.1.1.43.x.13
Panic Alarm
Selected
1.1.1.43.x.14
Robbery Alarm
Selected
1.1.1.43.x.15
Flood alarm
Selected
1.1.1.43.x.16
Gas Alarm
Selected
1.1.1.43.x.17
Medical Alarm
Selected
1.1.1.43.x.18
Zones Sabotage Tamper
Selected
1.1.1.43.x.19
Siren tamper
Selected
1.1.1.43.x.20
Radio device jamming
Selected
1.1.1.43.x.21
Tamper App
Selected
1.1.1.43.x.26
Bus I/O expansions tamper
Selected
Indices
Parameters
Configurations necessary to guarantee
Grade 2 certification
1.1.1.43.x.27
Bus keypad tamper
Selected
1.1.1.43.x.28
RFID tamper
Selected
1.1.1.43.x.29
Safetouch tamper
Selected
1.1.1.43.x.30
Touch Tamper
Selected
1.1.1.43.x.31
Bus power supply station or
isolator tamper
Selected
1.1.1.43.x.32
Bus radio concentrator
tamper
Selected
1.1.1.43.x.33
Bus siren tamper
Selected
1.1.1.43.x.34
Alarm communication device
tamper
Selected
1.1.1.43.x.35
IP expansion tamper
Selected
1.1.1.43.x.36
IP video expansion tamper
Selected
1.1.1.43.x.42
Remote communications
tamper
Selected
1.1.1.43.x.43
GSM concentrator jamming
Selected
1.1.1.43.x.44
False code
Selected
1.1.1.43.x.45
Zone Fault
Selected
1.1.1.43.x.46
Siren fuse fault
Selected
1.1.1.43.x.47
Radio control fault
Selected
1.1.1.43.x.48
Power supply unit fuse fault
Selected
1.1.1.43.x.49
Power supply unit battery
fault
Selected
1.1.1.43.x.50
Radio output battery fault
Selected
1.1.1.43.x.51
Bus siren battery fault
Selected
1.1.1.43.x.52
No power supply unit network
Selected
1.1.1.43.x.53
Radio zone battery fault
Selected
1.1.1.43.x.54
Radio control battery fault
Selected
1.1.1.43.x.55
Input voltage level fault
Selected
1.1.1.43.x.56
Output voltage level fault
Selected
1.1.1.43.x.57
Zones RX monitoring
Selected
1.1.1.43.x.58
Outputs RX monitoring
Selected
1.1.1.43.x.59
Output fault
Selected
1.1.1.43.x.60
Camera fault
Selected
1.1.1.43.x.61
No GSM/GPRS coverage
Selected
1.1.1.43.x.62
Telephone line fault
Selected
1.1.1.43.x.63
Failed communication fault
Only set selected
1.1.1.43.x.64
Robbery zone fault
Selected
1.1.1.43.x.65
Failed activation fault
Only set selected
1.1.1.43.x.66
IP Expansion fault on bus
Selected
1.1.1.43.x.67
Motion sensor jamming fault
Selected
1.1.1.43.x.70
I/O expansion Bus Fault
Selected
1.1.1.43.x.71
Keypad Bus Fault
Selected
1.1.1.43.x.72
Reader Bus Fault
Selected
1.1.1.43.x.73
Safe Touch Bus Fault
Selected
1.1.1.43.x.74
Touch Bus Fault
Selected
1.1.1.43.x.75
Isolator Power Supply Unit
Bus Fault
Selected
1.1.1.43.x.76
Radio Concentrator Bus Fault
Selected
1.1.1.43.x.77
Siren Bus Fault
Selected
1.1.1.43.x.78
Alarm Communication Device
Bus Fault
Selected
1.1.1.43.x.79
IP Expansion Bus Fault
Selected
1.1.1.43.x.80
IP Video Expansion Bus Fault
Selected
1.1.1.43.x.86
Control Panel Battery Fault
Selected
1.1.1.43.x.87
Control Panel Power Supply
Mains Outage
Selected
1.1.1.43.x.88
Control panel pstn fault
Selected
1.1.1.43.x.89
Control panel GSM fault
Selected
1.1.1.43.x.90
Control panel IP fault
Selected
1.1.1.43.x.91
Control panel voice synthesis
fault
Selected
1.1.1.43.x.94
Auxiliary power supply fuse
fault
Selected
1.1.1.43.x.95
Bus power supply fuse fault
Selected
1.1.1.43.x.96
Siren power supply fuse fault
Selected
1.1.1.43.x.97
Control panel power supply
unit fault
Selected
1.1.1.43.x.98
Control panel bus fault
Selected
1.1.1.43.x.99
Telephone line fault
Selected
1.1.1.43.x.100
No GSM network
Selected
1.1.1.43.x.101
No GPRS network
Selected
1.1.1.43.x.102
Date lost
Selected
1.1.1.43.x.103
Inactivity
Selected
1.1.1.43.x.106
Zone test
Selected
1.1.1.43.x.107
User logged in
Selected
1.1.1.43.x.108
L2 forced ON
Selected
1.1.1.43.x.109
L3 forced ON
Selected
1.1.1.43.x.110
Negligence
Selected
1.1.1.43.x.111
Alarm log
Selected
1.1.1.43.x.113
Reset alarms
Selected
1.1.1.43.x.114
Stop alarms
Selected
1.1.1.43.x.115
Stop telephone calls
Selected
1.1.1.43.x.116
Timed activation error
Selected
1.1.1.43.x.119
Technical programming
Selected
1.1.1.43.x.120
Control panel in service
Selected
1.1.1.43.x.123
Reset system alarms
Selected
1.1.1.43.x.124
Stop system alarms
Selected
1.1.1.43.x.125
Stop system telephone calls
Selected
Summary of Contents for VEDO 2.6 Series
Page 99: ...99...