38
The "pre-alarm" Burglar alarm delay Timer is the time that passes between zone violation and Alarm event generation. During the Burglar alarm
delay, the enabled checking devices will emit an audible alert.
= 0 sec [Reg. 49]
The Activation delay after alarm is the time that must pass before the violated area which generated the alarm event can be activated again.
If the Enable activation timer is associated with an Area, and if the Timer is active and in its START phase, the activation requirements for the area
- originating from the Control devices - will be satisfied. If the Timer is active but in is STOP phase, the activation requests will NOT be satisfied.
If the Enable deactivation timer is associated with an Area, and if the Timer is active and in its START phase, the deactivation requirements for
the area - originating from the Control devices - will be satisfied. If the Timer is active but in is STOP phase, the deactivation requests will NOT be
satisfied.
When this function is enabled, every Area to be activated will automatically carry out an Alarm Signal Reset.
Allows you to enter a specific area code that will be digitally transmitted by the communicator if the zones associated with that area generate
alarms or events requiring notification to a monitoring control panel. It is useful when systems are shared between multiple users, because in these
circumstances the Customer Code is not sufficient to identify unequivocally the source of the alarm call.
Allows you to associate the activation of the area that you are configuring, with the activation of one or more other areas. Supposing you are working
on Area 8, if you select Area 1 and Area 2 in its group of checkboxes, Area 8 will activate automatically when Area 1 and Area 2 are both activated.
It is possible to select one area only, for example Area 1. In this case, simply activating Area 1 will also activate Area 8.
If selected, ignores the activation delays of the areas activated as a consequence of the areas in AND.
Checkbox, allows activation as a consequence of the areas in AND even in the presence of a 'not ready for activation' state. In the case of a zone
not ready for activation, if this cannot be excluded, it generates an alarm.
BURGLAR ALARM DELAY (SECONDS)
ACTIVATION DELAY AFTER ALARM (MINUTES)
ENABLE ACTIVATION TIMER
ENABLE DEACTIVATION TIMER
AUTO-RESET ALARMS
AREA CODE
AREAS IN AND
INSTANT ACTIVATION OF AREAS IN AND
FORCED ACTIVATION OF AREAS IN AND
AREAS IN AND PANEL: