75
4. System Verification
4.1 CONTROL PANEL CHECK (REAL TIME)
This chapter will show how to:
This function allows you to check the system status in real time.
Providing for each element information on the status of every single
parameter.
Signals:
general signal
peripheral active
presence of anomalies, sabotage or faults
presence of alarms or peripheral absent
• check the system status using the function "Control panel check (Real
Time)"
• verify the system configurations for grade 2 certification to ENEN50131
and "EN50131 grade 2 + incert" using the function “Verify compliance..."
Below is the list of the parameters verified:
ZONES - OUTPUTS - AREAS
Element Parameters
Zones
• Open
• Alarm
• Fault
• Sabotage
• Not ready **
• ON
• Chime
• Excluded
• Isolated *
• Absent *
• Active
• Testing
• Masked
• Battery low ***
• Monitored ***
• Fault - inactivity
• inhibited
* with isolated condition and absent
at 0 means that the zone is active.
** valorised only if the conditions for
activation are present
*** radio only
Output
• on
• off
• absent*
• isolated*
• fault
• tamper**
• battery low**
• monitoring
* with isolated condition and absent
at 0 means that the zone is active.
** radio only
Area
• Deactivated
• Activated in total
• Activated in p1
• Activated in p2
• Not ready for activation
• In alarm
• Sabotage in progress
• Anomaly
• Alarm log
• Not ready for total activation
• Not ready for p1 activation
• Not ready for p2 activation
• Alarm in progress
• Zones excluded on the area
(sabotage, anomaly, zone or
zones testing)
• Input active time
• Output active time
CONTROL DEVICES
Element Parameters
Keypad
• Active
• Isolated
• Absent
• No input tamper
• Bus error
• Supply voltage error
• Device locking in progress
RFID reader
• Active
• Isolated
• Absent
• No input tamper
• Bus error
• Device locking in progress
Safetouch
Touch devices
• Active
• Isolated
• Absent
• No input tamper
• Bus error
• Supply voltage error
• Output short circuit
• Device locking in progress
CONTROL PANEL ALARMS/SABOTAGE
Element Parameters
Alarms
• Burglar
• 24H
• Fire
• Panic
• Robbery
• Flooding
• Gas
• Medical
Sabotage
• Wire zones tamper
• Siren/radio output tamper
• Radio device jamming
• Tamper free 0
• Tamper free 1
• Tamper free 2
• Tamper free 3
• Tamper free 4
• BUS I/O expansion tamper
• BUS keypad tamper
• BUS RFID tamper
• BUS Minitouch tamper
• BUS Planux tamper
• BUS power supply station/
isolator tamper
• BUS Radio expansion tamper
• BUS siren tamper
• Alarm communication device
tamper
• IP expansion tamper
• IP video expansion tamper
• Tamper bus free_0
• Tamper_bus_free_1
• Tamper_bus_free_2
• Tamper_bus_free_3
• Tamper_bus_free_4
• Remote communication
tamper
• GSM jamming
• False code
ANOMALIES
Element Parameters
Areas anomalies
• Bus siren fuse fault
• Radio control fault
• Bus power supply unit fuse
fault
• Bus power supply unit battery
• Radio siren battery
• Bus siren battery
• Bus power supply network
• Radio zone battery
• Radio control battery
• Bus expansion input voltage
level anomalous
• Bus expansion output voltage
level anomalous
• Zones rx monitoring
• Sirens rx monitoring
• Output fault
• Camera fault
• No bus expansion GSM GPRS
network
• Bus expansion telephone
line fault
• IO expansion fault
• Keypad fault
• RFID reader fault
• Safetouch fault
• Touch device fault
• Isolator power supply station
from bus
• Radio concentrator fault
from bus
• Siren fault from bus
• Alarm communication device
fault
• IP expansion fault
• IP video expansion fault
System
Anomalies
• Control panel battery
• Mains power supply
• PSTN fault
• GSM fault
• IP fault
• Voice synthesis fault
• Intercom fault
• Domotics fault
• AUX fuse fault
• Bus fuse fault
• Siren fuse fault
• Voltage low
• Control panel bus fault
• Telephone line bus fault
• No GSM network
• No GPRS network
• Date and time not set
EXPANSIONS
Element Parameters
Expansion
• Outputs shorting
• V+ aux voltage error
• Power supply voltage error
• Bus error
• No input tamper
• Absent
• Isolated
• Active
Radio expansion
• Technical fault
• Input voltage low
• 485 bus communication
• Jamming
• Tamper
• Absent
• Isolated
• Active
GSM
• No GSM expansion card
• No SIM
• GSM antenna fault
• No GSM network
• No GPRS network
• Sabotage - Jamming
• SIM expired
Power supply
units
• Output 03 short circuit
• Output 02 short circuit
• Output O1 short circuit
• 230/110 V supply error
• Battery error
• Aux 2 voltage error
• Aux 1 voltage error
• Output voltage error
• Input voltage error
• Supply voltage error
• Bus error
• Tamper
• Absent
• Isolated
• Active
Isolators
• Output voltage error
• Input voltage error
• Input bus error
• Tamper
• Absent
• Isolated
• Active
Summary of Contents for VEDO 2.6 Series
Page 99: ...99...