Calibration
98-150471-A02
Chapter 6: Configuration
6-15
Confi
guration
6.2.7
To make a line up procedure
The SAILOR 900 VSAT High Power has been tested at the factory and online on a live
satellite link to calibrate the TX polarisation unit. You can fine-tune the TX polarization by
doing a line up as described below. To do the line up, do as follows:
1. Open your Internet browser and enter the IP address of the ACU. The default IP address
is
http://192.168.0.1
.
2. Create a VSAT modem profile and a satellite profile using the previously created VSAT
modem profile (See
To set up a service profile for calibration
3. Go to the page
SERVICE > Line up
. As soon as the antenna is in tracking mode and
points to the satellite, the text next to
Status
shows:
Please wait. Improving
tracking.
This may take up to 2 minutes.
4. Wait until the text shows:
Ready for activation
.
5. Click the button
Activate lineup
and wait until the status field shows
Antenna ready
.
Follow the instructions from your service provider.
Note
The ship must not move during the line-up procedure.
Figure 6-11: Web interface: SERVICE, Line up: Ready for activation
Step 3
Step 4
SAILOR900HP.book Page 15 Monday, July 18, 2016 12:44 PM