List of ADU events
98-150471-A02
Appendix G: System messages
G-5
System messages
0A03D-0
Antenna ERROR
Ele DDM
shutdown
As Azi DDM shutdown but detected by the
elevation motor control.
0A03E-0
Antenna ERROR
PMM shutdown
As Azi DDM shutdown but detected by the
polarisation motor control.
0A03F-0
Antenna WARNING AMB timing
This indicates a busy situation. It may occur
during installation procedures. No user
interaction is required unless it occurs
repeatedly.
0A040-0
Antenna WARNING VIM cable attn
The output power cannot be controlled
correctly. Check the Tx chain.
0A041-0
Antenna WARNING BUC voltage low The voltage for the BUC is too low,
probably caused by a malfunctioning VIM
or BUC.
0A042-0
Antenna WARNING BUC voltage
high
The voltage for the BUC is too high
probably caused by a malfunctioning VIM.
0A043-0
Antenna WARNING LNB voltage low The voltage for the LNB is too low probably
caused by a malfunctioning VIM/TIM or
LNB.
0A044-0
Antenna WARNING LNB voltage high The voltage for the LNB is too high
probably caused by a malfunctioning
VIM/TIM.
0A045-0
Antenna WARNING PMM fan
The fan is not working or the tacho input
from the fan is not connected. Check fan
cable and fan.
0A046-0
Antenna WARNING Antenna
temperature
The temperature of the antenna is too high.
Check if the fan is working.
0A047-0
Antenna ERROR
VIM PLL lock
The PLL of the VIM/TIM is out of lock.
Check the 10 MHz reference signal.
0A048-0
Antenna WARNING VIM tuner lock
The PLL of the second receiver (DVB) is out
of lock. Check the 10 MHz reference signal.
0A049-0
Antenna WARNING Azi encoder slip
A slip of the azimuth encoder has been
detected. If this event is not resolved by
itself after some time, check the belt and
encoder of the azimuth axis.
Error code
(ID)
Unit
Severity
Description
Explanation
Table G-1: ADU event messages (Continued)
SAILOR900HP.book Page 5 Monday, July 18, 2016 12:44 PM