Calibration
6-8
Chapter 6: Configuration
98-150471-A02
4. Click
SERVICE > Calibration
.
5. Select
Enable
in the section
Azimuth calibration (active satellite profile)
.
6. Click
Apply
.
7. Switch on the modem.
Azimuth calibration (user controlled)
To make a user-controlled azimuth calibration, do as follows:
1. On the page
SERVICE > Calibration
, in the Satellite drop down list select
User
defined
.
2. Type in the longitude and polarisation skew of the satellite. The polarisation skew is
provided by the satellite operator, it is typically 0 degrees. For satellite data see
www.lyngsat.com.
3. Select the polarisation of a transponder and type in its frequency and symbol rate.
Figure 6-7: Web interface: SERVICE, Calibration
Note
Check that the satellite transponder is visible from the location of the installation
and that it is at an elevation angle between 10 and 70 degrees.
Important
The calibration function is not able to verify the correctness or precision
of the supplied longitude. It is therefore important to supply the correct
longitude including the first decimal.
SAILOR900HP.book Page 8 Monday, July 18, 2016 12:44 PM