List of ACU events
98-150471-A02
Appendix G: System messages
G-11
System messages
08100-0
ADM ERROR
PSM low voltage
(22 V)
The ADM measures a different antenna voltage
than expected. If the problem is not solved by a
restart, and the PSM is not reporting any errors, the
ADM is probably defective.
08101-0
ADM ERROR
PSM high voltage
(48 V)
The ADM measures a different antenna voltage
than expected. Check for short circuit of the
antenna coax connector. If the problem is not
solved by a restart, and the PSM is not reporting
any errors, the ADM is probably defective.
08102-0
ADM ERROR
PSM 5 V power
Internal voltage supply error of the ADM.
08103-0
ADM ERROR
ADM hotswap
The ACU is not able to supply the correct voltage
to the antenna. Check for short circuits in coax
cable and the antenna
08104-0
ADM ERROR
Antenna
communication
The ACU cannot communicate with the antenna.
Check cable and antenna.
08107-0
ADM ERROR
ADM FPGA load
The ADM FPGA cannot be initialised and loaded.
08108-0
ADM ERROR
TX Power
Detector
calibration
The power detector calibration is not valid.
08109-0
ADM ERROR
Antenna XIM data There is a mismatch in the antenna configuration
data. Either the PCM or the VIM in the antenna are
malfunctioning or one of them has been replaced.
In the latter case, select which is the original device
in the web interface and restart the system.
0810A-0
ADM ERROR
ADM production
data
Production data has been corrupted.
0810B-0
ADM ERROR
Antenna software
version
An error has occurred during upload of software to
the antenna, the antenna software version is not as
expected. Either the software in the ACU does not
meet the minimum version required by the
antenna, the software image in the ACU is
corrupted or the upload procedure failed because
of a communication error.
0810C-0
ADM ERROR
File system
integrity
One or more file system partitions are corrupt. You
may have lost your settings and collected statistics.
If restarting the system does not help, contact your
service partner.
Error code
(ID)
Unit
Severity
Description
Explanation
Table G-2: ACU event messages (Continued)