Chapter 3: Installation
98-150471-A02
3.4
Installation of the ACU
The following sections describe the installation and grounding of the ACU.
3.4.1
To install the ACU
A cable relief bracket is already mounted when receiving the ACU. The cable relief is a
simple system to secure cables with cable strips. It offers a number of holders to which you
can secure the cables from the ACU. To install the 19” rack version of the ACU, do as
follows:
1. Slide the ACU into a 1U space in a 19” rack.
2. Make sure that the air intakes on the side of the unit are not blocked.
3. Mount the screws in each side through the holes in the front and fasten the screws to
the rack. Make sure that the unit is mounted securely according to the requirements for
your 19” rack.
4. Connect all cables. See
Interfaces of the SAILOR 900 VSAT High Power ACU
1 for a description of the ACU connectors.
5. Set the On/Off switch at the front panel to On.
For a description of the connectors see
has additionally a LAN connector at the front for accessing the service port from the ACU
front panel.
Figure 3-22: ACU, On/off switch
Figure 3-23: ACU, LAN connector at the front: Service port
Set to ON
Service port
SAILOR900HP.book Page 24 Monday, July 18, 2016 12:44 PM