Page 20
CET-16
Service Manual
Connect Treated Water Line
Referring to Water Supply Lines (page 10) and Figure 2-3, verify that the
water supply fine has been extended from the SteamerGard water
treatment system to the SteamCraft V properly. Connect the treated water
supply lin
e
to the SteamCraft V as described below.
1. Refer to
the SteamerGard installation manual and verify that it has
been installed properly for this application.
2.
Verify that a check valve has been installed between the SteamerGard
water treatment system and the SteamCraft V.
3. Remove the SteamCraft V rear panel by removing six screws (figure 2-
15) that hold it in place. Save the screws.
4. Referring to figure 2-19, inspect the SteamCraft V to verify that the
treated water supply bulkhead coupling has been properly installed
and securely attached to the steam generator feed line inside the
steamer.
5. Flus
h
the treated water supply Iine before connecting it to the steam
generator intake bulkhead coupling.
6.
Apply pipe dope or teflon tape to the threads of the treated water
supply fine, and securely connect the supply fine to the steam gener-
ator intake bulkhead coupling.
7. Turn on the treated water supply, and check the lines for signs of
leakage, both outside and inside the steamer
8. If no further work is required inside the SteamCraft V, secure the rear
panel in place using six mounting screws (figure 2-l5).
Referring to Free Air Vented Drain Lines (page 11), verify that the drain
fines meet capacity and venting requirements. Connect the SteamCraft V
dram outlet to the outlet extension and drain fines as described below.
1. The SteamCraft V drain outlet (figure 2-20) is a 1-1/4" NPT pipe
protruding from
the back
of the unit. An elbow connects this drain
outlet to the drain extension pipe assembled during site preparation.
2
.
Refer to figure 2-20. The outlet extension fine has a free air vented
connection to floor drain or fines leading to the floor drain
3. When assembling the pipes and fittings of the drain outlet extension,
apply a hardening type pipe sealant to the threads, and thread them
together FINGER TIGHT ONLY. DO NOT USE A WRENCH.
Printe
d
4/90
Connect Drain Line
Summary of Contents for SteamCraft V
Page 56: ...Page 54 CET 16 Service Manual Figure 5 1 Block Diagram Printed 4 90...
Page 59: ...CET 16 Service Manual Page 57 Figure 5 2 Control Board Printed Circuit Board Printed 4 90...
Page 73: ...Page 72 CET 16 Service Manual Figure 6 1 MAJOR COMPONENT GROUPS...
Page 80: ...CET 16 Service Manual Page 79 Figure 6 6 ELECTRICAL COMPONENTS ASSEMBLY Printed 4 90...
Page 82: ...CET 16 Service Manual Page 81 Figure 6 7 FAN ASSEMBLY Printed 4 90...
Page 84: ...CET 16 Service Manual Page 83 Figure 6 8 CONDENSER AND DRAINAGE SYSTEMS Printed 4 90...
Page 86: ...CET 16 Service Manual Page 85 Figure 6 9 STEAM GENERATOR ASSEMBLY Printed 4 90...
Page 88: ...CET 16 Service Manual Page 87 Figure 6 10A DOUBLE WATER INLET ARRANGEMENT Printed 4 90...
Page 90: ...CET 16 Service Manual Page 89 Figure 6 10B SINGLE WATER INLET ARRANGEMENT Printed 4 90...