background image

All phases of this installation must comply with the

 NATIONAL, STATE & LOCAL CODES

.  In the absence of local codes, the installa-

tion must conform with 

National Electric Code -- ANSI/NFPA 70 or “LATEST REVISION.”

Dwg. No. X730377 P02

18-AB33D2-3

INSTALLATION
OPERATION
MAINTENANCE

IMPORTANT — 

This Document is customer property and is to remain with this unit.  Please return to service information pack upon completion of work.

Manufactured Housing
Package Cooling
W/  Optional Electric Heat
2-1/2 - 4 Ton

Model:

TCM030F1
TCM036F1
TCM042F1
TCM048F1

 

HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

WARNING:

©  2001 American Standard Inc. All rights reserved

Since the manufacturer has a policy of continuous product and product data improvement,
it reserves the right to change design and specification without notice.

Summary of Contents for TCM030F1

Page 1: ...ustomer property and is to remain with this unit Please return to service information pack upon completion of work Manufactured Housing Package Cooling W Optional Electric Heat 2 1 2 4 Ton Model TCM030F1 TCM036F1 TCM042F1 TCM048F1 HAZARDOUS VOLTAGE DISCONNECT POWER BEFORE SERVICING WARNING 2001 American Standard Inc All rights reserved Since the manufacturer has a policy of continuous product and ...

Page 2: ...er instal lation the following recommendations must be considered Select a location that will permit unobstructed airflow into the condenser coil and away from the fan discharge and permit unob structed service access into the compressor compartment Sug gested airflow clearances and service clearances are given in Figure 2 NOTE Unit shipped for horizontal installation The discharge air from the co...

Page 3: ...t of heavy canvas NOTE Do not draw the canvas taut between the solid ducts FILTER INSTALLATION AIR FILTERS Filters are to be used with the TCM030 048F heating cooling units The basic unit does not have filters in it However a filter frame accessory is offered that will allow filters to be installed within the unit Otherwise a filter rack must be installed by the installer in the duct work Affix th...

Page 4: ... B C D E F G H J K 1 W 2 W 3 W 4 W F 0 3 0 M C T 5 7 4 6 2 8 7 9 8 1 3 4 1 5 5 6 3 6 1 3 9 2 2 1 8 1 7 1 6 1 5 2 1 6 1 1 0 1 7 1 6 1 3 0 2 6 1 5 5 2 F 6 3 0 M C T 2 9 2 7 7 7 9 9 0 4 3 2 1 6 1 5 2 1 8 5 8 1 6 1 3 4 2 F 2 4 0 M C T 1 9 1 7 9 7 2 0 1 3 4 3 4 1 6 1 3 1 1 9 1 4 2 F 8 4 0 M C T 3 9 2 7 1 8 4 0 1 0 5 3 4 3 2 6 6 3 6 1 3 9 2 4 1 4 3 2 2 6 1 5 2 1 6 1 1 0 1 7 1 9 1 4 2 ...

Page 5: ...M C T 4 1 5 5 6 3 6 1 3 9 2 6 1 5 1 2 1 8 7 4 T I U D N O C 4 1 1 D N A 4 3 R O F S T U O K C O N K F 8 4 0 M C T 4 3 2 6 6 3 6 1 3 9 2 2 1 4 1 8 7 4 TCC030 048F OUTLINE REAR E C N A R A E L C E C I V R E S D E D N E M M O C E R K C A B 0 6 E D I S T F E L 0 0 3 E D I S T H G I R 0 4 2 E D I S T N O R F 0 0 3 ...

Page 6: ...t OVER CURRENT PROTECTION The branch circuit feeding the unit must be protected as shown on the unit rating plate POWER WIRING The power supply lines must be run in weathertight conduit to the disconnect and into the bottom of the unit control box Provide strain relief for all conduit with suitable connectors Provide flexible conduit supports whenever vibration transmission may cause a noise probl...

Page 7: ...OR FAN TO OPERATE IN HEATING 7 SOME THERMOSTATS PROVIDE THE G SIGNAL IN THE COOLING MODE ONLY TO PROVIDE THE G SIGNAL IN THE HEATING MODE AN ACCESSORY RELAY IS REQUIRED SEE FIG 3 FOR PROPER CONNECTIONS 8 FOR COOLING ONLY OMIT THE ELECTRIC HEATER ASSOCIATED POWER WIRES AND THE W SIGNAL THERMOSTAT WIRE 9 FIG 4 DEMONSTRATES CONNECTION OF THE TWO STAGE ELECTRIC HEAT THERMOSTAT ACCESSORY ONLY FOR FURTH...

Page 8: ...ection Is the condensate line properly sized run trapped and pitched Is the filter of the correct size and number Is it clean and in place Is the wiring properly sized and run according to the unit wiring diagram Are all the wiring connections including those in the unit tight Has the unit been properly grounded and fused with the recom mended fuse size See Wiring Data Is the thermostat level corr...

Page 9: ...e CC contacts and starts the compressor CPR and the outdoor fan motor ODM When the call for cooling is complete the compressor contactor CC outdoor fan motor ODM and indoor fan relay F is de energized HEATING ELECTRIC HEATERS On a call for heat power from the thermostat is received at W1 which energizes the AH contactor coil The AH contactor closes powering the heater provided all element limits a...

Page 10: ...ical cleaning electrical components and wiring for possible replacement and connection tightness condensate drain for cleaning unit duct connections to see that they are physically sound and sealed to the unit casing unit mounting support for structural integrity the unit for obvious unit deterioration MAINTENANCE PERFORMED BY SERVICEMAN HEATING SEASON Complete the unit inspections and service rou...

Page 11: ...l This limited warranty applies to product installed on or after 10 1 2001 where product is manufactured after 1 1 2000 This limited warranty is not retroactive to any installations prior to 10 1 2001 or on product produced prior to 2000 THE LIMITED WARRANTY AND LIABILITY SET FORTH HEREIN ARE IN LIEU OF ALL OTHER WARRANTIES AND LIABILITIES WHETHER IN CONTRACT OR IN NEGLIGENCE EXPRESS OR IMPLIED IN...

Page 12: ...yarelimitedtofurnishing F O B WarrantorfactoryorwarehousereplacementpartsforWarrantor sproductscoveredunderthis warranty Warrantorshallnotbeobligatedtopayforthecostoflostrefrigerant Noliabilityshallattachto Warrantoruntilproductshavebeenpaidforandthenliabilityshallbelimitedsolelytothepurchasepriceof theequipmentunderwarrantyshowntobedefective THE WARRANTY AND LIABILITY SET FORTH HEREIN ARE IN LIEU...

Reviews: