CET-16 Service Manual Page 9
Electric Power Line
Furnishing and installing the electrical power Iines, switches, fuse boxes,
connectors and their accessories is the responsibility of the owner and/or
installer. Figure
2-6
illustrates an electrical layout recommended by
Cleveland Range. When installing the electrical power lines and acces-
sories, observe the following instructions.
1. In the United States, install the electrical power lines in accordance
with
local codes and/or the National Electri
c
Code, ANSI/NFPA No.
70-1990 (USA).
2.
In Canada, install the electrical power lines in accordance with local
codes and/or the Canadian Electrical Code, CSA Standard C22.1
(Canada).
3. Install the proper size disconnect switch, circuit breaker or fuses, and
wire and conduit to conform to all local codes and the national codes
cite
d
above. See table 2-3 for wire requirements.
Table 2-3. Minimum Wire Requirements
LIN
E
KILO
LIN
E
WIRE
VOLTAGE
WATTS
AMPS*
GAUGE**
208
16.7
46
6
220
153
40
6
240
18.0
43
6
380/220
153
23
10
415/240
18.0
25
10
440
153
20
10
480
18.0
22
10
*All 3 Phase
**Use copper wire rated for 75° C.
Printed 4/90
Summary of Contents for SteamCraft V
Page 56: ...Page 54 CET 16 Service Manual Figure 5 1 Block Diagram Printed 4 90...
Page 59: ...CET 16 Service Manual Page 57 Figure 5 2 Control Board Printed Circuit Board Printed 4 90...
Page 73: ...Page 72 CET 16 Service Manual Figure 6 1 MAJOR COMPONENT GROUPS...
Page 80: ...CET 16 Service Manual Page 79 Figure 6 6 ELECTRICAL COMPONENTS ASSEMBLY Printed 4 90...
Page 82: ...CET 16 Service Manual Page 81 Figure 6 7 FAN ASSEMBLY Printed 4 90...
Page 84: ...CET 16 Service Manual Page 83 Figure 6 8 CONDENSER AND DRAINAGE SYSTEMS Printed 4 90...
Page 86: ...CET 16 Service Manual Page 85 Figure 6 9 STEAM GENERATOR ASSEMBLY Printed 4 90...
Page 88: ...CET 16 Service Manual Page 87 Figure 6 10A DOUBLE WATER INLET ARRANGEMENT Printed 4 90...
Page 90: ...CET 16 Service Manual Page 89 Figure 6 10B SINGLE WATER INLET ARRANGEMENT Printed 4 90...