Page 56
CET-16 Service Manual
cont. (208,230, or 460 VAC). The primary circuit components are: the
transformer primary coil, the fan motor, and the steam generator and fan
heater elements. Cleveland Range supplies these components in groups
compatible with most international power systems. To identify the
electrical characteristics of the primary circuit components, refer to the
Product Identification plate on the left side of the unit (Figure 6-1), and the
Performance Data plate on the fan motor (Fan Assembly, Figure 6-1).
When servicing, repairing, or replacing any of the primary circuit, com-
ponents, observe the requirements of the Product Identification and the
Performance Data plates, and pay particular attention to the following.
1. For operation at 208-240 VAC, the primary windings of the stepdown
transformer most be wired in paraIlel.
2. For operation at 440-480 VAC the primary windings of the stepdown
transformer must be wired in series.
3. Steam generator and fan heater elements are available for 208,230, or
460 VAC operation. When testing or replacing steam generator or fan
heater elements, refer to Heater Elements and Tables 5-1 and 5-2.
4. Normally, the SteamCraft V control panel is factory set for 60 Hz
operation. For 50 Hz operation, Cleveland Range supplies the control
panel with jumper wire JP1 removed. See Figure 5-2. If installation
requires removal of JP1 in the field, the conformal coating must be
repaired with Cleveland Range approved coating material.
Table 5-1. Steam Generator Heater Elements
PART NO.
WATTS
VOLTS
OHMS +5%
101223
2660
205
16
1012231
2660
230
48
1012232
2660
460
78
101224
5300
205
8
1012241
5300
240
10
1012242
5300
480
39
Table 5-2. Fan Heating Elements
PART NO.
WATTS
VOLTS
OHMS +5%
101227
300
208
139
1012271
300
230
172
1012272
300
460
666
Printed 4/90
Summary of Contents for SteamCraft V
Page 56: ...Page 54 CET 16 Service Manual Figure 5 1 Block Diagram Printed 4 90...
Page 59: ...CET 16 Service Manual Page 57 Figure 5 2 Control Board Printed Circuit Board Printed 4 90...
Page 73: ...Page 72 CET 16 Service Manual Figure 6 1 MAJOR COMPONENT GROUPS...
Page 80: ...CET 16 Service Manual Page 79 Figure 6 6 ELECTRICAL COMPONENTS ASSEMBLY Printed 4 90...
Page 82: ...CET 16 Service Manual Page 81 Figure 6 7 FAN ASSEMBLY Printed 4 90...
Page 84: ...CET 16 Service Manual Page 83 Figure 6 8 CONDENSER AND DRAINAGE SYSTEMS Printed 4 90...
Page 86: ...CET 16 Service Manual Page 85 Figure 6 9 STEAM GENERATOR ASSEMBLY Printed 4 90...
Page 88: ...CET 16 Service Manual Page 87 Figure 6 10A DOUBLE WATER INLET ARRANGEMENT Printed 4 90...
Page 90: ...CET 16 Service Manual Page 89 Figure 6 10B SINGLE WATER INLET ARRANGEMENT Printed 4 90...