CET-16 Service Manual Page 21
Final Setup And Checkout
This is a simple test procedure to verify that the electrical, water, and
drain lines have been property connected to the SteamCraft V. The test
also verifies basic operation of the steamer. For a more complete test of
the SteamCraft V functions, perform the Function Test on page 23.
Setup
1
.
Refer to Assembly (page 14) and verify that racks, guard, and cover
are properly
positioned in the steamer compartment.
2
.
Refer to figure 2-21, and dose the drain valve (handle points toward
right side of the unit).
Printed 4/90