CET-16 Service Manual Page 7
Table 2-2. Minimum Feed Water Quality Requirements
Total Dissolved Solids
less than 60 pans per million
Silica
less than 13 pans per million
Alkalinity
less than 20 pans per minion
pH factor
greater than 7.5
SteamCraft V Operating Location
When selecting an operating location for the SteamCraftV, observe the
following criteria.
• The SteamCraft V takes up a minimum of counter space. Figure 2-4
illustrates the dimensions and clearance
s
required. The 3'' clearance at
the rear includes spacing for the water inlet strainer and fittings, and
the maximum size (2" NPT) drain fittings.
• Figure 2-4 illustrates a left hand door hinge. A right hand door hinge
(model # DHR-5)
is also available for the SteamCraft V.