steamer shuts off and cannot be turned on until the
problem is corrected. Refer to Troubleshooting in
Chapter 4.
8. WATER WATER is a low water safety warning. It indicates
that the water level in the steam generator is too
low. Water cannot be heated until the steam
generator has enough water to operate, safely.
When the steamer is first turned on, the WATER
safety warning normally displays until the steam
generator fills to the proper level.
9. DIGITAL TIME DISPLAY
• The DIGITAL TIME DISPLAY shows cooking
time.
• When MANUAL cooking is selected, the TIME
DISPLAY counts up from 00 so the operator can
watch elapsed time until the proper cooking time
has been reached.
• When TIMED cooking
is selected, the TIME
DISPLAY counts down from the time set using
the left and right TIME SET touch pads.
• A green light to the right of the TIME DISPLAY
flashes on and off when the dock is counting.
This green light turns off when the dock stops
counting.
• Counting stops when the steamer door is
opened or when the steamer compartment is not
up to temperature.
Printed 4/90
Summary of Contents for SteamCraft V
Page 56: ...Page 54 CET 16 Service Manual Figure 5 1 Block Diagram Printed 4 90...
Page 59: ...CET 16 Service Manual Page 57 Figure 5 2 Control Board Printed Circuit Board Printed 4 90...
Page 73: ...Page 72 CET 16 Service Manual Figure 6 1 MAJOR COMPONENT GROUPS...
Page 80: ...CET 16 Service Manual Page 79 Figure 6 6 ELECTRICAL COMPONENTS ASSEMBLY Printed 4 90...
Page 82: ...CET 16 Service Manual Page 81 Figure 6 7 FAN ASSEMBLY Printed 4 90...
Page 84: ...CET 16 Service Manual Page 83 Figure 6 8 CONDENSER AND DRAINAGE SYSTEMS Printed 4 90...
Page 86: ...CET 16 Service Manual Page 85 Figure 6 9 STEAM GENERATOR ASSEMBLY Printed 4 90...
Page 88: ...CET 16 Service Manual Page 87 Figure 6 10A DOUBLE WATER INLET ARRANGEMENT Printed 4 90...
Page 90: ...CET 16 Service Manual Page 89 Figure 6 10B SINGLE WATER INLET ARRANGEMENT Printed 4 90...