Page 12
CET-16 Service Manual
WARNING
DEATH, INJURY, AND EQUIPMENT DAMAGE
could result from improper installation of the drain
outlet lines.
Improper installation of these lines could void the
SteamCraft V warranty. The following restrictions
are critical to the safety of personnel and equip-
ment, and must not be violated under any cir-
cumstances.
Do not run the drain line into PVC pipe, or any
other drain material that cannot sustain 180° F.Do
not connect more than two pieces of equipment to
one common drain line.
Do
not connect the drain outlet extension
line
directly to a floor drain or sewer line without free
air venting.
1. The drain lines must be installed in compliance with the Basic
Plumbing Code of the Building Officials and Code
Administrators International, Inc. (BOCA), and the Food Service
Sanitation Manual of the Food and Drug Administration (FDA).
2. The pipe size used to extend the drain outlet to an open drain is
determined by the cumulative length of pipe and/or number of
elbow fittings required to reach the open drain.
• If the drain outlet extension requires six feet or less of pipe,
and no more than two elbows are required, use 1/4'' pipe and
fittings.
• If the drain outlet extension requires six to twelve feet of pipe,
or requires more than three elbows, use 2" pipe and fittings.
3. The drain line must have a gravity flow from the SteamCraft V
drain outlet to the floor drain.
4. There must be a minimum of one-inch clearance between the
end of the drain line and the top of the floor drain to assure free
air venting.
5. When assembling the pipe and fittings of the drain line, apply a
hardening type pipe sealant to the threads, and tighten them
together
FINGER TIGHT ONLY. DO NOT USE A WRENCH
.
INSTALLATION INSTRUCTIONS
After selecting and preparing the SteamCraft V operating location,
the steamer can be unpacked, positioned, and installed. This
section of Chapter 2 details inspecting, positioning, and connecting
the SteamCraft V to the power, water, and drain lines already
prepared. After final setup and testing, the SteamCraft V is ready for
years of reliable operation.
Printe
d
4/90
Summary of Contents for SteamCraft V
Page 56: ...Page 54 CET 16 Service Manual Figure 5 1 Block Diagram Printed 4 90...
Page 59: ...CET 16 Service Manual Page 57 Figure 5 2 Control Board Printed Circuit Board Printed 4 90...
Page 73: ...Page 72 CET 16 Service Manual Figure 6 1 MAJOR COMPONENT GROUPS...
Page 80: ...CET 16 Service Manual Page 79 Figure 6 6 ELECTRICAL COMPONENTS ASSEMBLY Printed 4 90...
Page 82: ...CET 16 Service Manual Page 81 Figure 6 7 FAN ASSEMBLY Printed 4 90...
Page 84: ...CET 16 Service Manual Page 83 Figure 6 8 CONDENSER AND DRAINAGE SYSTEMS Printed 4 90...
Page 86: ...CET 16 Service Manual Page 85 Figure 6 9 STEAM GENERATOR ASSEMBLY Printed 4 90...
Page 88: ...CET 16 Service Manual Page 87 Figure 6 10A DOUBLE WATER INLET ARRANGEMENT Printed 4 90...
Page 90: ...CET 16 Service Manual Page 89 Figure 6 10B SINGLE WATER INLET ARRANGEMENT Printed 4 90...