CET-16 Service Manual Page 63
Figure 5-5. Door Sensor Location
Compartment Temperature Switch
A snap action thermostatic switch attaches to the underside of the
steamer compartment near the front left corner of the steam generator.
The switch closes when the compartment temperature rises above 180-
200 F and controls tile timing circuit during TIMED operation. If frozen
food, for example, causes the compartment temperature to drop below
the switch set point, the switch prevents the timer from starting its
countdown until the compartment temperature rises and the switch
closes. Also, if the door opens during a TIMED cycle and the
compartment cools, the switch opens and interrupts the tuning circuit
countdown until the compartment reheats. Thus
,
the action of the
compartment temperature switch and the timing circuit adjust cooking
duration to compensate for factors that affect cooking time: product
temperature (fresh or frozen), compartment loading, and opening of the
compartment door during a cooking cycle.
Printed 4/90
Summary of Contents for SteamCraft V
Page 56: ...Page 54 CET 16 Service Manual Figure 5 1 Block Diagram Printed 4 90...
Page 59: ...CET 16 Service Manual Page 57 Figure 5 2 Control Board Printed Circuit Board Printed 4 90...
Page 73: ...Page 72 CET 16 Service Manual Figure 6 1 MAJOR COMPONENT GROUPS...
Page 80: ...CET 16 Service Manual Page 79 Figure 6 6 ELECTRICAL COMPONENTS ASSEMBLY Printed 4 90...
Page 82: ...CET 16 Service Manual Page 81 Figure 6 7 FAN ASSEMBLY Printed 4 90...
Page 84: ...CET 16 Service Manual Page 83 Figure 6 8 CONDENSER AND DRAINAGE SYSTEMS Printed 4 90...
Page 86: ...CET 16 Service Manual Page 85 Figure 6 9 STEAM GENERATOR ASSEMBLY Printed 4 90...
Page 88: ...CET 16 Service Manual Page 87 Figure 6 10A DOUBLE WATER INLET ARRANGEMENT Printed 4 90...
Page 90: ...CET 16 Service Manual Page 89 Figure 6 10B SINGLE WATER INLET ARRANGEMENT Printed 4 90...