CET-16 Service Manual Page 5
Figure 2-1. Schematic Installation Diagram
1. Electrical conduit
access to terminal
block inside
back cover.
• Canadian steamers are supplied with six feet of
flexible conduit for compliance with Canadian
Standards Association.
2. A separate disconnect switch with fuses sized to
line amps (see Table 2-3) MUST be installed for
each steamer.
• Furnished and installed by others.
3. The steamer MUST be electrically grounded by the
Installer.
4. Untreated cold water connection (1/4'' NPT).
• Steam Generator and Condenser supply for
units without water treatment system.
• Condenser supply for units with SteamerGard
water treatment system.
5. Access for treated cold water connection.
• Steam Generator supply for units with Steamer-
Gard water treatment systems.
• Requires additional parts and installation by
authorized service representative.
6. Drain outlet connection with 1-1/4" NPT.
• Outlet extension connects to drain outlet.
• Outlet extension line has free air vented connec-
tion to floor drain.
Summary of Contents for SteamCraft V
Page 56: ...Page 54 CET 16 Service Manual Figure 5 1 Block Diagram Printed 4 90...
Page 59: ...CET 16 Service Manual Page 57 Figure 5 2 Control Board Printed Circuit Board Printed 4 90...
Page 73: ...Page 72 CET 16 Service Manual Figure 6 1 MAJOR COMPONENT GROUPS...
Page 80: ...CET 16 Service Manual Page 79 Figure 6 6 ELECTRICAL COMPONENTS ASSEMBLY Printed 4 90...
Page 82: ...CET 16 Service Manual Page 81 Figure 6 7 FAN ASSEMBLY Printed 4 90...
Page 84: ...CET 16 Service Manual Page 83 Figure 6 8 CONDENSER AND DRAINAGE SYSTEMS Printed 4 90...
Page 86: ...CET 16 Service Manual Page 85 Figure 6 9 STEAM GENERATOR ASSEMBLY Printed 4 90...
Page 88: ...CET 16 Service Manual Page 87 Figure 6 10A DOUBLE WATER INLET ARRANGEMENT Printed 4 90...
Page 90: ...CET 16 Service Manual Page 89 Figure 6 10B SINGLE WATER INLET ARRANGEMENT Printed 4 90...